beautypg.com

1 - ratings & data - natural gas & propane gas – Pennco 15B045FE User Manual

Page 4

background image

4

Table 1

- Ratings and Capacities

Model No.

Input

Mbh

(1)

Heating

Capacity

Mbh

(1)

Net AHRI

Rating Water

Mbh

(2)

**

AFUE Elect.

Ign.

No. Of

Burners

Recommended Air

Cushion Tank

(3)

Water

Content

(Gals.)

15B045

45

37

32

82.0%

1

15

2.4

15B070

70

57

50

82.0%

2

15

4.0

15B096

96

79

69

82.0%

2

30

4.0

15B120

120

98

85

82.0%

3

30

5.6

15B145

145

119

103

82.0%

3

30

5.6

15B170

170

140

122

82.0%

4

30

7.2

15B195

195

160

139

82.0%

4

30

7.2

15B245

245

201

174

82.0%

5

30

8.8

15B295

295

242

210

82.0%

6

60

10.4

1 - RATINGS & DATA - NATURAL GAS & PROPANE GAS

EXPLANATORY NOTES
-- All boilers are design certified for installation on noncombustible floor.
-- Recommended chimney height 20 feet. In special cases where conditions permit, chimney height may be

reduced to 10 feet. Refer to the latest revision of NFGC part 11.
-- Electric service to be 120 Volts, 15 Amps, 60 Hz.
-- The MEA number for the this boiler is 19-79-E.

(1) Input rating for sea level to 2,000 ft. (610m) above sea level.

United States, over 2000 ft (610m) above sea level. Reduce input rate 4% for every 1,000 ft (304m) above sea

level.

(2) Net AHRI Water Ratings shown based on piping and pickup allowance of 1.15. Consult manufacturer before selecting

boiler for installations having unusual piping and pickup requirements, such as intermittent system operation,

extensive piping systems, etc.
For forced hot water systems where boiler and all piping within area to be heated, boiler may be selected on basis of

its heating capacity.

(3) Tank sized for non-ferrous baseboard or radiant panel systems. Increase size for cast iron baseboard and

radiation.

STANDARD EQUIPMENT: Boiler Jacket, Cast Iron Boiler Battery, High Limit Control, Intermittent Electric Ignition Pilot

System, Vent Damper Relay, Circulator With Return Piping To Boiler, Main Gas Burners, Gas Control (Includes Automatic Gas

Valve, Gas Pressure Regulator, Intermittent Pilot, Safety Shutoff, Pilot Flow Adjustment, Pilot Filter), A.S.M.E. Relief Valve, Drain

Valve, Spill Switch, Rollout Switch, Combination Gas Control, Automatic Vent Damper. Not Shown Are: Wiring Harness,, Non-

linting Safety Pilot.

This manual is related to the following products: