beautypg.com

Networked single loop system connections & wiring, Systems design technical guide 25, Tb3 stat gnd 24vac r shld t tb2 rec – Orion System Systems Design User Manual

Page 25: Gnd ain 2 ain 1 +5v tb2, Cx14 network driver rn3

background image

Systems Design Technical Guide

25

Networked Single Loop System Connections & Wiring

Figure 7: Networked Single Loop System With CommLink & MiniLink PD - Non-Modular VAV/Zone
Controllers

Networked Single Loop System With CommLink 5 & MiniLink PD

V

A

V/Zone

Controller

V

A

V/Zone

Controller

Connect

T

o

Next

Non-Modular

V

A

V/Zone Controller

On Branch Circuit

T

ypical Sing

le Loop Netw

or

k

ed System

W

ith MiniLink P

olling De

vice And CommLink 5

W

ith Non-Modular V

A

V/Zone Contr

oller

s

Non-Modular

Non-Modular

VAVZ 2
FOR ENCL.
W/TERM BLKS

YS102218
REV2

E

X

PAN

S

ION

D

'S

TAT

S

PACE

SENSOR

MADE IN USA

WATTMASTER CONTROLS INC

HI(VAV)

LOW(VVT)

VE
L

O

C

IT

Y

ADDRESS

OFF

ON

EPROM

PAL

485
DRV

EE
PR

O

M

93C66

(-)LO

GND

OUT

IN

setra

26

311

R

5WD4MZZCWM1

RANGE:

0-

1.5"WC

Exc:

5

V

D

C

O

utpu

t:

.25

-4

.25

VDC

S/N:

26

2041

3

2705

AC
TU
ATO

R

1

0

OE282

TB3

STAT

GND

24VAC

R

SHLD

T

TB2

REC

Note:

Either

A

System

A

Service

T

ool Or

A

P

C

Manager

TS II,

Modular System Manager

,

A

Modular

With Prism II Software

Installed Can Be Used

T

o

Program

And

Configure

The Orion System.

VAVZ 2
FOR ENCL.
W/TERM BLKS

YS102218
REV2

E

X

PAN

S

ION

D

'S

TAT

S

PACE

SENSOR

MADE IN USA

WATTMASTER CONTROLS INC

HI(VAV)

LOW(VVT)

VE
L

O

C

IT

Y

ADDRESS

OFF

ON

EPROM

PAL

485
DRV

EE
PR

O

M

93C66

(-)LO

GND

OUT

IN

setra

26311

R5WD4MZZCWM1

RANGE:

0-

1.5"WC

Ex

c:

5

VDC

Output

:

.25

-4

.2

5

V

D

C

S/N:

26

2041

3

2705

AC
TU
ATO

R

1

0

OE282

TB3

STAT

GND

24VAC

R

SHLD

T

TB2

REC

VAVZ 2
FOR ENCL.
W/TERM BLKS

YS102218
REV2

E

X

PAN

S

ION

D

'S

TAT

S

PACE

SENSOR

MADE IN USA

WATTMASTER CONTROLS INC

HI(VAV)

LOW(VVT)

VE
L

O

C

IT

Y

ADDRESS

OFF

ON

EPROM

PAL

485
DRV

EE
PR

O

M

93C66

(-)LO

GND

OUT

IN

setra

26

311

R

5WD4MZZCWM1

RANGE:

0-

1.5"WC

Exc:

5

V

D

C

O

utpu

t:

.25

-4

.25

VDC

S/N:

26

2041

3

2705

AC
TU
ATO

R

1

0

OE282

TB3

STAT

GND

24VAC

R

SHLD

T

TB2

REC

Line

V

oltage

24 V

AC - Size

T

ransformer

For Required V

A

Load

V

A

V/Zone

Controller

Non-Modular

Connect Power

T

o

Next

Non-Modular

V

A

VZone

Controller

GND

24 V

A

C

Back V

iew

1

10 V

AC T

o

24 V

A

C

Power Pack

Note:

CommLink Must

Be Set For Multiple Loop

Operation When Used

In

This

Application

Front V

iew

CommLink 5

Serial #

COMPUTER

USB

10/100

ETHERNET

DIAG

485 LOOP

POWER

ACT

LNK

HIGH

LOW

BAUD

R(+)

24V

GND

SHLD

T(

-)

MULT

IPLE

SINGLE

LOOP

Local

Local

24 V

A

C

(6 V

A

)

EPROM

U3

U5

RAM

CX2

1

U2

R1

C3

U4

CX3

CX4

YS101818P552
PROCESSORPBOARD

CX5

C1

U1

R2

CX1

CX6

WDOG

U6

PHILIPS

D1

P1

X1

C2

C4

0-10V

4-20mA

THERM

R27

R31

D4

GND

24V

AC

TB1

D5

C11

U12

LED 2

POWER

V1

R25

R26

C7

CX15

CX13

PROC.

DRIVER

LOOP
DRIVER

LOCAL LOOP

GND

AIN 2

AIN 1

+5V

TB2

P4

OFF=0-5V

AIN2

AIN1

0-10V

4-20mA

THERM

TB3

U15

LD5

LD6

U13

C8

LED 1

RV1

R4

VREF

CX2

U11

YS101900PMINILINK
POLLING
DEVICE
REV. 1

OFF

1 2 4 8 16 32

CX14

NETWORK
DRIVER

RN3

SHLD

SHLD

T

T

TB4

R

R

U14

NETWORK
LOOP

P5

ADD

P3

R24

LD4

C9

U10

RN2

SW1

R30

X2

R29

R28

C10

U6

CX6

CX1

U7

U1

X1

C3

C1

R3

CX7

MiniLink PD

Network

Connect T

o

Other Non-Modular

V

A

V/Zone

Controllers

On Loop

SHLD

T

R

T

ypical T

erminal Blocks.

All

W

iring T

o

Be T T

o

T

, SHLD (G)

T

o

SHLD (G) & R T

o

R

T

G

R

485

LO

OP

System Manager T

ouch Screen II

Modular System Manager

Connect

T

o

Modular I/O

Connectors Located On

Back Of

The Modular

System Manager

.

WHITE (T)

DRAIN WIRE (SHLD)

BLACK (R)

RED (24 V

AC)

Line V

oltage

24 V

A

C

(6 V

A

)

CLEAR (GND)

GREEN (GND)

Line V

oltage

24 V

A

C

(8 V

A

)

RELA

Y

CONT

ACT

RA

TING IS 1

AMP

MAX @ 24 V

A

C

RS-485 COMMUNICA

TION LOOP

. WIRE

“R

T

O“

R

”,“

T

T

O

“T

”“

S

H

L

D

T

O“

S

H

L

D

FA

N

RELA

Y

2

RELA

Y

3

RELA

Y

4

RELA

Y

5

RELA

Y

COMMON

IC DIGIT

A

L

SENSOR

2

IC

EXP

ANSION

2

ST

A

T

IC

PRESSURE

AI1

= SPC (SP

A

CE

TEMPERA

TURE SENSOR)

AI2 AI3 AI4 AI5 AI7

A01 A02

= SA

T

(SUPPL

Y

A

IR

TEMPERA

TURE SENSOR)

= RA

T

(RETURN

AIR

T

EMPERA

TURE SENSOR)

= OA

T

(OUTDOOR

AIR

T

EMPERA

TURE SENSOR)

= SUCTION PRESSURE SENSOR

= SP

ACE

TEMPERA

TURE SENSOR SLIDE

A

DJUST

OR VOL

T

AGE RESET

SOURCE

= ECONOMIZER (2-10 VDC OUTPUT)

= SUPPL

Y

F

AN VFD (0-10 VDC OUTPUT)

ANALOG INPUT

JUMPER SETTINGS

MUST

BE SET

AS SHOWN FOR

PROPER OPERA

TION

24 V

AC POWER ONL

Y

W

ARNING!

POLARITY

MUST BE OBSER

VED

OR THE CONTROLLER WILL

BE DAMAGED

www

.orioncontrols.com

AI1

AI2

AI3

AI4

THERM

THERM

THERM

THERM

THERM

THERM

4-20mA

4-20mA

4-20mA

4-20mA

4-20mA

4-20mA

0-10V

0-10V

0-10V

0-10V

0-10V

0-10V

0-5V

0-5V

0-5V

0-5V

0-5V

0-5V

AI5

AI7

ANALOG INPUT

JUMPER

SETTINGS

W

a

ttMaster Label

#LB102033-01

OE332-23-VCMX-A

VCM-X CONTROLLER

WARNING

OBSERVE
POLARITY

RELA

Y

CONT

ACT

RA

TING IS 1

A

MP

MAX @ 24 V

A

C

RS-485 COMMUNICA

TION LOOP

. WIRE

“R”

T

O

“R”,

“T”

T

O

“T”

“SHLD”

T

O

“SHLD”

FA

N

RELA

Y

2

RELA

Y

3

RELA

Y

4

RELA

Y

5

RELA

Y

COMMON

IC DIGIT

AL

SENSOR

2

IC

EXP

A

NSION

2

ST

A

TIC

PRESSURE

ANALOG INPUT

JUMPER SETTINGS

MUST

BE SET

AS SHOWN FOR

PROPER OPERA

TION

24 V

A

C POWER ONL

Y

W

A

RNING!

POLARITY

MUST BE OBSER

VED

OR THE CONTROLLER WILL

B

E DAMAGED

AI1

AI2

AI3

AI4

THERM

THERM

THERM

THERM

THERM

THERM

4-20mA

4-20mA

4-20mA

4-20mA

4-20mA

4-20mA

0-10V

0-10V

0-10V

0-10V

0-10V

0-10V

0-5V

0-5V

0-5V

0-5V

0-5V

0-5V

AI5

AI7

ANALOG INPUT

JUMPER

SETTINGS

W

a

ttMaster Label

#LB102073-01-A

Rev

.: 1A

www

.aaon.com

www

.orioncontrols.com

VCM-X MODULAR E-BUS CONTROLLER

Orion No.:OE332-23E-VCMX-MOD-A

AAON No.:

V07150

AI1

= SPC (SP

ACE

T

EMPERA

TURE SENSOR)

AI2 AI3 AI4 AI5 AI7

A01 A02

= SA

T

(SUPPL

Y

AIR

TEMPERA

T

URE SENSOR)

= RA

T

(RETURN

AIR

TEMPERA

TURE SENSOR)

= OA

T

(OUTDOOR

AIR

TEMPERA

TURE SENSOR)

= SUCTION PRESSURE SENSOR (FROM EXP

. MODULE)

= SP

ACE

T

EMPERA

TURE SENSOR SLIDE

A

DJUST

OR VOL

T

AGE RESET

S

OURCE

= ECONOMIZER (2-10 VDC OUTPUT)

= SUPPL

Y

F

AN VFD (0-10 VDC OUTPUT)

LE

D

B

L

IN

K

CODES

LED

N

A

M

E

STATU

S

1

STATU

S

2

NO

RMA

L

OP

E

R

ATIO

N

0

1

SAT

F

AIL

1

2

OAT

F

AIL

2

2

SP

C

F

A

IL

3

2

MODU

LE

A

L

ARM

4

2

MEC

H

C

OOL

FA

IL

1

3

M

E

C

H

HE

AT

F

A

IL

2

3

FAN

P

ROOF

FA

IL

3

3

DIRTY

F

ILTE

R

4

3

EMERGE

NCY

S

H

U

T

D

OWN

5

3

LOW

S

AT

1

4

HIGH

S

A

T

2

4

CO

NT.

T

EMP

C

OOL

F

A

IL

3

4

CO

NT.

T

EMP

H

EAT

F

A

IL

4

4

PUSH

BUTTON

OV

R

1

5

ZONE

OV

R

2

5

OUTP

UT

FO

RC

E

A

CTIV

E

0

6

E-BUS

CONNECT

OR

HV

AC Unit Controller

Line V

oltage

24 V

A

C

(8 V

A

)

Line V

oltage

24 V

A

C

(8 V

A

)

Line V

oltage

24 V

A

C

(8 V

A

)

Note:

For System

Manager

TS II Wiring,

See Figure 1 On Page 19.

For Optional CommLink, USB-Link,

And Computer Connections,

See Figures 10 & 1

1

On Pages 28 & 29.

Modular

Service T

ool SD