Networked single loop system connections & wiring, Networked single loop system with minilink pd only, Systems design technical guide 22 – Orion System Systems Design User Manual
Page 22: Zone
![background image](https://www.manualsdir.com/files/800433/content/doc022.png)
Zone
Zone
Systems Design Technical Guide
22
Networked Single Loop System Connections & Wiring
Figure 4: Networked Single Loop System With MiniLink PD Only - Modular VAV Zone Controllers
Networked Single Loop System with MiniLink PD Only
E
X
PAN
S
ION
D
'S
TAT
S
PACE
SENSOR
POWER
/
C
O
M
M
ST
A
T
MADE IN USA
WATTMASTER CONTROLS INC
HI(VAV)
LOW(VVT)
VE
L
O
C
IT
Y
ADDRESS
OFF
ON
EPROM
PAL
485
REC
DRV
EE
PR
O
M
93C66
(-)LO
GND
OUT
IN
setra
26311
R5WD4MZZCWM1
RANGE:
0-
1.5"WC
Ex
c:
5
VDC
Output
:
.25
-4
.25
V
D
C
S/N:
26
2041
3
2705
AC
TU
ATO
R
1
0
OE282
Line V
oltage
24 V
A
C
(8 V
A
)
Connect T
o
Other V
A
V/Zone
Controllers
On Loop
Connect T
o
Other V
A
V/Zone
Controllers
On Loop
Connect T
o
Other V
A
V/Zone
Controllers
On Loop
Power/Comm
Board
Power/Comm
Board
V
A
V/Zone
Controller
V
A
V/Zone
Controller
V
A
V/Zone
Controller
Line V
oltage
Line V
oltage
HV
AC Unit Controller
24 V
AC - Size
T
ransformer
For Required V
A
Load
24 V
AC - Size
T
ransformer
For Required V
A
Load
(1 MEG)
Note:
A
Maximum Of 6 V
A
V/Zone Controllers Can Be
Connected
T
o
Each Branch Circuit.
A
T
otal Of 16
Controllers
Are
Allowed Per Power/Comm Board. Use
Additional Power/Comm Boards For Systems
That
Exceed 16 Controllers. See
The V
A
V/Zone Controller
Wiring Diagram For Power/Comm Board
T
ransformer
Sizing
And Circuit Design Information.
TB2
TB2
VAC
VAC
F1
F1
25
25
4A
4A
24
24
SHLD
SHLD
T
T
R
R
POWER
POWER
LD1
LD1
TB1
TB1
C1
C1
POWER & COMM
DIST. BOARD
YS101856
REV. 0
POWER & COMM
DIST. BOARD
YS101856
REV. 0
P5
P5
P4
P4
P3
P3
P1
P1
D1
D1
V1
V1
R1
R1
P2
P2
COMMP
IN
COMMP
IN
POW
E
R
&
C
O
M
M
OUT
POW
E
R
&
COMM
OUT
Connect
T
o
Next Modular
V
A
V/Zone Controller
On Branch Circuit
Connect
T
o
Next
V
A
V/Zone Controller
On Branch Circuit
SHLD
T
R
T
ypical T
erminal Blocks.
All
W
iring T
o
Be T T
o
T
, SHLD (G)
T
o
SHLD (G) & R T
o
R
T
G
R
485
LO
OP
T
ypical Sing
le Loop Netw
or
k
ed System
W
ith MiniLink P
olling De
vice Onl
y
W
ith Modular V
A
V/Zone Contr
oller
s
System Manager T
ouch Screen II
Connect
T
o
Modular I/O
Connectors Located On
Back Of
The Modular
System Manager
.
Modular System Manager
Modular
Note:
Either
A
System
Manager
TS II,
A
Modular System
Manager
,
A
Modular
Service
T
ool Or
A
P
C
With Prism II Software
Installed Can Be Used
T
o
Program
And
Configure
The Orion
System.
E
X
PAN
S
ION
D
'S
TAT
S
PACE
SENSOR
POWER
/
C
O
M
M
ST
A
T
MADE IN USA
WATTMASTER CONTROLS INC
HI(VAV)
LOW(VVT)
VE
L
O
C
IT
Y
ADDRESS
OFF
ON
EPROM
PAL
485
REC
DRV
EE
PR
O
M
93C66
(-)LO
GND
OUT
IN
setra
26311
R5WD4MZZCWM1
RANGE:
0-
1.5"WC
Ex
c:
5
VDC
O
utpu
t:
.25
-4
.25
VDC
S/N:
26
2041
3
2705
AC
TU
ATO
R
1
0
OE282
E
X
PAN
S
ION
D
'S
TAT
S
PACE
SENSOR
POWER
/
C
O
M
M
ST
A
T
MADE IN USA
WATTMASTER CONTROLS INC
HI(VAV)
LOW(VVT)
VE
L
O
C
IT
Y
ADDRESS
OFF
ON
EPROM
PAL
485
REC
DRV
EE
PR
O
M
93C66
(-)LO
GND
OUT
IN
setra
26311
R5WD4MZZCWM1
RANGE:
0-
1.5"WC
Exc:
5
V
D
C
Output
:
.25
-4
.25
V
D
C
S/N:
26
2041
3
2705
AC
TU
ATO
R
1
0
OE282
Local
Local
24 V
A
C
(6 V
A
)
EPROM
U3
U5
RAM
CX2
1
U2
R1
C3
U4
CX3
CX4
YS101818P552
PROCESSORPBOARD
CX5
C1
U1
R2
CX1
CX6
WDOG
U6
PHILIPS
D1
P1
X1
C2
C4
0-10V
4-20mA
THERM
R27
R31
D4
GND
24V
AC
TB1
D5
C11
U12
LED 2
POWER
V1
R25
R26
C7
CX15
CX13
PROC.
DRIVER
LOOP
DRIVER
LOCAL LOOP
GND
AIN 2
AIN 1
+5V
TB2
P4
OFF=0-5V
AIN2
AIN1
0-10V
4-20mA
THERM
TB3
U15
LD5
LD6
U13
C8
LED 1
RV1
R4
VREF
CX2
U11
YS101900PMINILINK
POLLING
DEVICE
REV. 1
OFF
1 2 4 8 16 32
CX14
NETWORK
DRIVER
RN3
SHLD
SHLD
T
T
TB4
R
R
U14
NETWORK
LOOP
P5
ADD
P3
R24
LD4
C9
U10
RN2
SW1
R30
X2
R29
R28
C10
U6
CX6
CX1
U7
U1
X1
C3
C1
R3
CX7
MiniLink PD
Note:
For System
Manager
TS II Wiring,
See Figure 1 On Page 19.
Modular
Modular
Modular
Service T
ool SD