SMTS II for GPC-XP Technical Guide

COMPONENTS & WIRING

7

SMTS II to GPC-XP Controller Wiring

Figure 5: System Manager TS II to GPC-XP Controller Wiring

.1

u

F

YS102178 R4

WQVGA Graphical Interface

WattMaster Controls, Inc

C24

R9

R7

R6

R5

R2

R1

C51

C39

C20

C19

C15

C14

C13

C12

C11

C10

C9

C7

C1

X3

8.00

Mhz

OFF

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1

u

F

.1

u

F

.1

u

F

.1

u

F

.1

u

F

.1

u

F

.1

u

F

.1

u

F

.1

u

F

.1

u

F

.1

u

F

.1uF

.1uF

.1

u

F

.1

u

F

.1

u

F

.1

u

F

1002

.1uF

1002

1002

.1uF

.1uF

.1uF

.1uF

LTC3824

1002

1002

1002

1002

1002

1002

66.000Mhz

MADE IN USA

330uF 50V

330uF

1002

SERIAL #

OP

T

4

OP

T

3

OP

T

2

OP

T

1

TERM

RTC

YS102178 R4

WQVGA Graphical Interface

WattMaster Controls, Inc

CAL

5V

3.3V

2.5V

J3

R34

R

16

R13

R8

R39

X2

R26

R17

R14

C24

U13

R49

R48

R47

R46

R45

R44

R43

R40

R37

R35

R32

R31

R29

R27

R24

R22

R12

R11

R10

R9

R7

R6

R5

R2

R1

L5

L4

D12

D11

D1

C51

C50

C45

C41

C39

C36

C20

C19

C18

C17

C16

C15

C14

C13

C12

C11

C10

C9

C8

C7

C6

C5

C4

C1

J1

R41

C23

C25

C26

R42

X3

R20

C27

C34

C40

U10

U11

C28

C29

R18

C35

D2

L1

R25

C31

R19

U9

R28

C32

R

30

R33

C30

R15

Q2

R21

R23

SW1

C2

C3

V1

R36

1002

R

R

S

S

T

T

T

S

R

+

+

1002

R

T

5V

GND

GPC-XP Controller -

Front View

BLACK (R)

BLACK (R)

BLACK (R)

RED (24 VAC)

RED (24 VAC)

To (24 VAC)
Transformer +

T

o

R

T

erminal On

GPC-XP

T

o

S

T

erminal On

GPC-XP

T

o

T

T

erminal On

GPC-XP

To (24 VAC)
Transformer -

BROWN (GND)

Line Voltage

24 VAC Transformer

5 VA Minimum

BROWN (GND)

WHITE (T)

WHITE (T)

WHITE (T)

BARE (S)

BARE (S)

BARE (S)

Run 2 Conductor Twisted
Pair W/Shield Cable.
WattMaster WR-LL-WG-18
Cable Or Equivalent From
System Manager TS To
VCB-X Controller

Run 2 Conductor 20 Ga. Minimum
Cable From System Manager TS
Terminals To 24 VAC Transformer.

System Manager TS - Back View

TERM

NOTE: For Stand-Alone
Installations (No CommLink
or MiniLink), Both TERM
Jumpers Must Be ON.
For All Applications With
CommLink(s) Or MiniLink(s),
Both Jumpers Must Be OFF.

OFF

OP

T

4

OP

T

3

OP

T

2

OP

T

1

SW1

NOTE: Dip Switch OPT1
Should Be Set To ON When
GPC-XP Is Set To High Speed.
OPT2 & OPT3

. As Of April 2014,

OPT4 Should Be Set To ON
By Default. Previous Versions
Should Be Set To OFF. If You
See Your Screen Is Not
Centered Correctly, Switch
OPT4 To The Opposite
Position.

Should Be

Set To OFF

CO

M
F

R

O

M
G

ND

CUT

TO

IS

O

L

A

T

E

WATTMASTER CONTROLS

YS102432 REV 3

LOOP COMM

GND

+24V

+5V

OUTPUTS

ADDRESS

ADD

1
2
4
8

16
32

POWER

EBUS

STATUS2

STATUS1

OUTPUTS

ANALOG

SERIAL #

OUTPUTS

RELAY

SH

R+

T-

BIN8

BIN7

BIN6

BIN5

BIN4

BIN3

BIN2

BIN1

BINARY
INPUTS

INPUTS

ANALOG

0-5

v

0-10

v

4-

2

0

m

A

AO

UT

1

-2

C14

R109

TB8

U19

U17

TB7

TB6

TB4

TB3

TB2

TB1

SW1

R97

R74

R6
1

R59

R5
5

R51

R47

R4
3

R4
1

R3
8

R21

R16

R14

D13

D12

D10

D9

D8

D7

D6

C46

C36

C21

RLY1

RLY2

RLY3

RLY4

COMMON

MADE IN USA

RLY1

RLY2

RLY3

RLY4

COMMON

AOUT1

AOUT2

AOUT3

AOUT4

GND

GND

1002

1002

.1uF

.1uF

AO

UT

3

-4

GND

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

.1uF

.01uF

LO
O

P

BAU

D

1

2

AI7

AI8

AI6

AI5

AI4

AI1

AI2

AI3

GND

GND

GND

GND

AI8

AI7

AI6

AI5

AI4

AI3

AI2

AI1

TH
E

R

M

VDC

300

300

300

300

300

300

300

300

COM

COM

COM

COM

D11

CONNEC

ON BOA
COMMLI

RELAY CONTACT
RATING IS 1 AMP
MAX @ 24 VAC

RS-485 COMMUNICATION LOOP. WIRE
“R” TO “R”, “T” TO “T” “SHLD” TO “SHLD”

RELAY 2

RELAY 6

RELAY 1

RELAY 5

RLY 1 =

VDC

OUTPUTS

AI1 =

+ 24 VDC

+ 5 VDC

GND

BI1 =

AO1 =

AI2 =

BI2 =

AO2 =

AI3 =

BI3 =

AO3 =

AI4 =

BI4 =

AO4 =

AI5 =

BI5 =

AI6 =

BI6 =

AI7 =

BI7 =

AI8 =

BI8 =

RLY 2 =

RLY 5 =

RLY 3 =

RLY 6 =

RLY 4 =

RLY 7 =

RLY 8 =

RELAY 3

RELAY 7

RELAY 4

RELAY 8

COMMON

COMMON

USB

PORT

E-BUS

PORT

NOTES:
1.) ANALOG INPUT JUMPER SETTINGS MUST BE
SET FOR YOUR SPECIFIC INPUT DEVICE
REQUIREMENT.

2.) IT IS RECOMMENDED THAT YOU WRITE THE
DESCRIPTION OF THE INPUT, AND/OR
OUTPUTS YOU ARE CONNECTING TO THE
CONTROLLER IN THE BOXES PROVIDED ABOVE
USING A PERMANENT MARKER (SHARPIE) FOR
FUTURE REFERENCE.

®

24 VAC POWER ONLY

WARNING! POLARITY MUST BE OBSERVED

OR THE CONTROLLER WILL BE DAMAGED

www.wattmaster.com

AI1

AI2

AI3

AI4

AI5

AI6

AI7

AI8

THE

R

M

4-20

mA

0-

10

V

0-

5V

ANALOG

INPUT

JUMPERS

LED BLINK CODES

LED NAME

STATUS1

STATUS2

NORMAL OPERATION

0

1

SCHEDULE OVERRIDE

0

2

OE338-23-GPC-XP

GPC-XP CONTROLLER

WattMaster Label

#LB102095

Rev.: 1C

+2

4

VA

C

GND