beautypg.com

Set the system baud rate, 10 key press beep, 11 alarm response – OpenEye CA-501J PTZ User Manual

Page 24: 12 password setting, Lock keys

background image

10

28563AA

Set the System Baud Rate

Press the 2 key to set the system baud rate.

Press Ż or Ź to change the setting (Default, 9600bps, 4800bps, 2400bps).

SYSTEM BAUD RATE

DEVICE TYPE

DEFAULT

9600

4800

2400

DOME CAMERA

(OPTIX 3)

9600 9600

4800

2400

DOME CAMERA

(PELCO-D)

2400 9600

4800

2400

DOME CAMERA

(PELCO-P)

4800 9600

4800

2400

1.10 KEY PRESS BEEP

Turn on/off the key beep. When this feature is on, the keyboard beeps each time a key is pressed.

1.

Press Ż or Ź to change the setting.

2.

Press ź to go to next item.

1.11 ALARM RESPONSE

Enable/Disable the alarm response function of the keyboard. The default setting is OFF.

When the alarm response is enabled:

a)

A buzzer beeps and the LCD display flashes when the keyboard receives an alarm signal

b)

After the alarm signal, when a user moves the joystick or presses a key, the keyboard will to link to the camera that
broadcast the alarm.

Press the Ż or Ź key to change the setting.

1.12 PASSWORD SETTING

Allows users to change the keyboard password. You must enter the new 4-digit password correctly twice to confirm the password
change.

LOCK KEYS

Press and hold the LOCK/UNLOCK key for three seconds to lock the keys of the keyboard and dim the LCD display. To unlock the
keys, press and hold the key again for three seconds.