INPUT (RF) LED Status
Normal Operation: LED Green
Non-Urgent Alarm: LED Yellow
• RF input low or high
• In AGC-On mode: Input RF power is low or high and AGC gets out of range
• In AGC-Off mode: OMI
totrms
is at the edge of its range
Urgent Alarm: LED Red
• RF-input is missing. RF input low or high
• In AGC-On mode: Input RF power is too low or too high and AGC is out of range
• In AGC-Off mode: OMI
totrms
is out of range
OUTPUT (P
OPT
) LED Status
Normal Operation: LED Green
Non-Urgent Alarm: LED Yellow
• The output power drops more than 0.5dB or increases more than 0.5dB (value can be adjusted by the user)
relative to the nominal output power.
The transmitter is still working, but with reduced performance. It may need to be sent to Olson for main-
tenance. Call first to get an RMA.
Urgent Alarm: LED Red
• The output power drops more than 1.0dB or increases more than 1.0dB (value can be adjusted by the user)
related to the nominal output power. The transmitter is not working properly. It may need to be sent to