Olson Technology OT-1000-HH Rev.X4 User Manual
Page 11

025-000573 Rev. X4
- 11 -
www.olsontech.com
Parameter Unit
Min.
Typ.
Max. Remark
Network Management Interface
Two RJ45 connectors for RS-485 bus
implementation:
Pin 1: RS-485 +
Pin 2: RS-485 –
Pin 3: Not used
Pin 4: Not used
Pin 5: Not used
Pin 6: Not used
Pin 7: Not used, opt. +24 V
DC
Pin 8: GND
Case: GND
Optical Properties
Parameter
Unit
Value
Wavelength
nm
ITU DWDM channel
Wavelength tuning range
GHz ±
100
Wavelength tolerance
(for full temperature range)
nm ±
0.07
Laser type
cooled DFB laser with optical isolator
Optical power
dBm 8
Optical power tolerance
dB ±
1.0
Optical power adjustment range
dB
0 … -3
Optical return loss
dB >
45
RIN (opt. return loss < -40 dB)
dBc/Hz <
-154
Typical Electrical Properties
Parameter
Unit
Value
RF-Frequency Range
MHz 47
–1,000
Flatness dB
<±0.5 @ 47 … 606MHz
<±0.75 @ 47 … 862MHz
<±1.5 @ 47 … 1,000MHz
Version “c”
C B N
Channel plan
CENELEC 42
PAL-B/G
NTSC 77
number of channels
TV / FM (-4dB) / QAM64 (-10dB)
42 / 0 / 0
36 / 0 / 0
74 / 0 / 0
OMI
%
4.1 4.1 4.1
Noise bandwidth
MHz
5.0 5.0 5.0
CNR Tx/Rx
dB
53 53 53
CNR Link 1
dB
51 51 51
CSO Tx/Rx
(pre-chirping adjusted to 10 km)
dBc
56
60 (< 6 MHz)
56
60 (< 6 MHz)
56
60 (< 6 MHz)
CSO and Link 1
(pre-chirping adjusted to 10 km)
dBc
50
56 (< 6 MHz)
50
56 (< 6 MHz)
50
56 (< 6 MHz)
CTB
dBc
62 62 62
Test Configurations
Configuration
Booster
EDFA
Fiber
Length
Rx