4) Move the connector back and forth on the moistened part
of the cloth, turning slightly and pressing lightly.
Slide the front surface of the connector, or connector
shaft, from the moist to the dry area, without breaking the
surface contact with the cloth, so that no cleaning agent
residue is left.
NOTICE
If the result of cleaning is not good, repeat the procedure.
5) Reconnect the connector or cover it immediately with a
dust cap.
Installing the OT-1000-HH
Please follow these instructions for correctly installing the transmitter module OT-1000-HH:
1) The OT-1000-HH is intended for mounting in 19-in EIA equipment racks.
2) Please observe rack safety (refer to rack vendor manuals).
Mount the chassis according to rack vendor requirements. Do not forget to use the grounding screw if required.
Connect power supply on the module’s rear with delivered powering cable only. Do not use other powering cable
from third-party vendors! Connect module RF and optical connections.
3) Be sure that the OT-1000-HH is going to be put into operation under the specified environmental conditions.
Avoid temperature shocks after transportation of the module and allow sufficient time to accommodate with the
environmental conditions at the operating site. Switch on the module at the rear power switch. After start, the
“Module” LED on the front will light Green and the other LED’s should monitor the status of the transmitter.
4) It is possible to connect the transmitter to an Olson network management controller OT-NEC-A by the rear
RS-485 interface. Typical (Ethernet) RJ45 cable connects the OT-NEC-A and the OT-1000-HH to establish the
RS-485 management bus. The pin out of the RJ45 cable is shown on page 11.
5) Set appropriate operating conditions.
Figure 4 — Rear of OT-1000-HH