Power-Up Sequence

• Be sure that the OT-1000-HH is put into operation under the recommended

environmental conditions. Avoid temperature shocks after transportation of the

OT-1000-HH and allow sufficient time to acclimate with the environmental conditions at the operating
site.

• Mount the OT-1000-HH on an appropriate sub-rack or an outdoor housing and provide the required

powering.

• After power on, the STATUS LED is Green.
• After this procedure, the LED’s should indicate the status of the transmitter.

Setting Appropriate Operating Conditions

Optical Output Signal

A fiber optic cable with an appropriate, cleaned connector can be connected to the optical output, in order to
feed a HFC network.

Keep in mind that the OT-1000-HH is a laser class 1M product (according to
IEC/EN 60825-1), which requires adequate safety precautions to avoid hazard to
people working with it.

The transmitter’s output power can be lowered from 0dB to -3dB. This feature is

normally used for multi-channel DWDM applications where optical power balancing is required. It is rec-
ommended to keep the nominal optical output power (0dB) in all other cases.