Maintenance, External power source, Battery – NavCom SF-2040 Rev.E User Manual
Page 34

SF-2040 User Guide - Rev. E
Maintenance
The NavCom equipment may be cleaned using a new
lint free cloth moistened with pure alcohol.
Connecters must be inspected and if necessary cleaned
before use. Always use the provided connecter
protective caps to minimize moisture and dirt ingress.
Cables should be regularly inspected for kinks and cuts
as these may cause interference and equipment failure.
Damp equipment must be dried at a temperature less
than +40°C (104°F), but greater than 5°C (41°F) at the
earliest opportunity.
External Power Source
If the SF-2040 is used with an external power cable
(
P/N
94-310060-3010), this must be connected to the
chosen external power solution in accordance with
Chapter 2 Interfacing\Electrical Power. It is important
that the external power source allow sufficient current
draw for proper operation. Insufficient supplied current
will cause damage to your external power source.
If your chosen external power source is a disposable
battery, please dispose of the battery in accordance
with your local regulations.
Battery
The battery pack contains Lithium Ion cells and should
be used with the supplied charger only (92-310046-
3001). Any short circuit battery contacts could result in
an explosion, and the release of toxic fumes. Do Not
store above 40°C (104° F) or below 0°C (32° F). Do Not
5-32