Step 12: Zap strap wires together in a neat bunch so that no wires
can fall into the motor.
Figure 5k.
Step 13: Zap strap wires to loop in the top of the capacitor.
Figure 5l.
Step 14: Test the power vent and make sure it is working properly.
When looking down at the top of the motor the fan should be spinning
counterclockwise. If it is spinning the wrong way or not at all it is wired
incorrectly. Put the top cover back on using the supplied replacement
screws.
Top Cover
Top Cover
Screws x 4 plcs
Screw Locations
x 4 plcs
Wind Baffle
Rain Skirt
Screw Locations
x 5 plcs
Top Separator
Step 1:
a) Remove the 4 outer screws
that fasten the Top Cover to
the termination
b) Remove the Cover.
PVVEX58-300
Motor Removal / Servicing
Step 2:
a) Remove the 4 outer screws
that fasten the Wind Baffle to
the termination.
b) Lower the Wind Baffle to
rest on the Rain Skirt.
Step 3:
a) Remove the 5 outer screws
that fasten the Top Separator
to the termination.
b) Remove the Top Separator.
Figure 5m.
Service