beautypg.com

Service – Montigo PVVEX58-300 User Manual

Page 13

background image

PVVEX58-300 & PVVEX510-300 Horizontal Power Vent

Page 13

XG0518 - 070714

Step 12: Zap strap wires together in a neat bunch so that no wires

can fall into the motor.

Figure 5k.
Step 13: Zap strap wires to loop in the top of the capacitor.

Figure 5l.

Step 14: Test the power vent and make sure it is working properly.

When looking down at the top of the motor the fan should be spinning

counterclockwise. If it is spinning the wrong way or not at all it is wired

incorrectly. Put the top cover back on using the supplied replacement

screws.

Top Cover

Top Cover

Screws x 4 plcs

Screw Locations

x 4 plcs

Wind Baffle

Rain Skirt

Screw Locations

x 5 plcs

Top Separator

Step 1:

a) Remove the 4 outer screws

that fasten the Top Cover to

the termination

b) Remove the Cover.

PVVEX58-300

Motor Removal / Servicing

Step 2:

a) Remove the 4 outer screws

that fasten the Wind Baffle to

the termination.

b) Lower the Wind Baffle to

rest on the Rain Skirt.

Step 3:

a) Remove the 5 outer screws

that fasten the Top Separator

to the termination.

b) Remove the Top Separator.

Figure 5m.

Service