Maintenance, Replacement parts, Troubleshooting – Montigo DHS User Manual
Page 18

Page 18
Hotshot Gas Fireplace Insert
XG0511 - 150203
Maintenance
Troubleshooting
The following is a troubleshooting chart of possible problems:
PROBLEM
CORRECTIVE ACTION
Noisy Pilot Flame
Locate pilot adjustment screw on gas
control valve. The flame is decreased
by turning adjustment screw clock-
wise.
Pilot won’t ignite
Disconnect remote wires and try to
light pilot. If pilot now works, remote
connections are faulty. Check wiring
diagram figure 13.
Main burner will
1. Check wiring (see figure 13).
not light
2. Check wall switch for proper con-
nection.
3. Check high limit switch.
If your fireplace still does not operate correctly, consult your dealer or the manufacturer.
All service and repairs should be performed by a qualified agency.
All spare parts and optional such as trim finishes and the wireless infrared remote control are available from your local dealer or the
manufacturer.
Replacement Parts
Standing Pilot - Replacement Parts List
Hotshot DHS Insert
NG Gas Valve
RGC1044R
LP Gas Valve
RGC1043R
NG Pilot
RPA024
LP Pilot
RPA025
NG Burner
Contact Local Montigo Dealer
LP Burner
Thermocouple
RPG001
Thermopile
RPG001
Piezo Ignitor
PIEZO
Pilot Tubing
RPTA03
Door
RDHS
Replacement Screen
RSCDHS
Log Set
RLGS19