Installation
Section 5: Wiring
The Fireplace A/C power and Power Vent harness's must be installed
before completing the installation of the H36PVN Fireplace. These
connections are made from the RH-Side of the fireplace, Figure 12
through Figure 12f.
Figure 12. Incoming A/C Power , (connect per. Local Codes).
Figure 12a. Remove Exterior Access Cover.
Install the Power Vent connections as described
below:
Step 1. Remove the exterior Access cover, shown Figure 12a .
Step 2. Locate all the Power vent connections & ports, Figure 12b .
Figure 12b. Locate Power vent connections.
Note: To access the fireplace electrical connections from the
firebox follow the procedures described in figure 22 through 26.
Power Vent,
& A/C Access
Cover
Power Vent,
Communica-
tion port.
Power vent communi-
cation conduit, A/C
connection port
Incoming A/C
Power Connection
Step 4. Place the cover plate on the Conduit, then tighten the strain
relief nut onto the threads protruding through backside of cover plate,
Figure 12e .
Step 3. Remove the Power Vent communication port cover from
cabinet, (as supplied) Figure 12c . (Philips head screwdriver
required).