beautypg.com

Periodic inspection/maintenance – MMD Equipment 185S-6C1 User Manual

Page 50

background image

5. Periodic Inspection/Maintenance

5-13


5.5.14 Change Oil Separator

[Every 2,000 hours]


When changing the oil separator, both cover and element must be replaced with new ones.

Even before the periodic interval time of replacement,

replace the oil separator whenever the oil consumption
increases and also oil is found mixed in the discharge air.

When consumption of the oil is still unusual even after

cleaning strainer in the scavenging orifice (See 5.5.7),
change the oil separator with a new one. (See 5.4)

When replacing oil separator, contact directly us or
distributor because it requires expert technical
knowledge.






5.5.15 Change Nylon Tubes

[Every 2,000 hours]

Replace nylon tubes used for the oil and air pipings.

When replacing nylon tube, contact directly us or distributor because it requires expert technical

knowledge.


5.6.16 Clean inside of Fuel Tank

[Every 2,000 hours]

Cleaning the inside of fuel tank. requires expert technical knowledge. So contact directly us or dis-

tributor.






A070229

Separator

casing

O-ring

Element

Cover

Separator cover

Oil

Separator