5. Periodic Inspection/Maintenance

5-9


5.5.6 Change compressor oil filter

[At 300 hours for the first change and every 1,000 hours thereafter]


Poor quality oil filters do not trap dust sufficiently and will cause damage to the bearings in a short period.

Procedure>

Remove the cartridge“1”, using a filter wrench.

Screw in the new cartridge“1”with the packing“2” coated
slightly with oil. (See 5.4)

After the packing touches the sealing face, further tighten it
by turning it 3/4-1 time with the filter wrench.

After installing the oil filter, check it for any leak during
operation.




5.5.7 Clean strainer in the scavenging orifice

[Every 500 hours]

Procedure>

Remove the pipe“1”, using a spanner.

First remove the bushing“2”.

Then remove the strainer“3”.

Wash the removed strainer“3”in diesel oil and blow

out “dust” by air blowing.

After finishing the cleaning, install the strainer“3”

again in the reverse procedure.


1

3

2

Use our genuine oil filter

H000049

1

2

Separator

receiver tank

A070193-1