4. Operation
4-9
A070304
4.3.6 Drain fuel tank
Opening the drain valve“2”fitted under the fuel
tank“1”, drain the condensate from the tank.
When completely drained, firmly close the drain
valve“2”.
Drain the condensate in container“3”,and then
dispose of condensate according to the designated
regulations.
4.3.7 Check fuel filter(sedimenter built-in type) for condensate
Whenever interval of periodical replacement of
Condensate in fuel filter comes or the warning lamp
Drain condensate accumulated goes on,in the filter.
①
Loosen drain valve “1” and then drain the condensed water
accumulated in the filter.
②
Make sure to tighten the drain valve “1” securely, after
draining the condensate.
③
Finally carry out air bleeding in fuel system, pushing the
priming pump “2” up and down. continue this operation
till the pump moves heavily.
Drain the condensate in container, and then dispose of
condensate according to the designated regulations.
A070268
1
2
3
2
1