Periodic inspection/maintenance – MMD Equipment 185S-6C1 User Manual
Page 47

5. Periodic Inspection/Maintenance
5-10
5.5.8 Change air filter element
[Every 500 hours]
Air filter is an important part which is crucial to machine's performance and life.
Be sure to use genuine parts.
<
Procedure>
①
After removing the cap“1”by loosening its latch“2”,
clean its interior properly.
②
Remove the element “3”and then replace it with a
new one.
(See 5.4)
③
When installing the cap“1”after replacing it, properly
push the element into the case“4”by hand and then
make sure that the hooks for fixing the cap are surely
set. Finally tighten it.
5.5.9 Change fuel filter (sedimenter built-in type)
[Every 500 hours]
<
Procedure>
①
Separate the sensor connector “1”(provided at the
lower part of fuel filter) from the main wiring por-
tion .
②
Loosen the drain valve “2”and then drain condensate
and residual fuel staying inside the filter into a con-
tainer etc.
③
Remove the cartridge “4”from the cover “3”, using
a filter wrench.
④
Remove the sensor assembly “5”from the cartridge “4”.
⑤
Install the sensor assembly “5”to the new cartridge
“
4”. (See 5.4)
⑥
New cartridge “4”please bind tight using a filter
wrench.
⑦
After finishing the installation, install the removed
connector “1” to where it was.
⑧
Finally, press the priming pump“6” up and down a
few times for air bleeding in fuel line. Continue it till
the pump moves heavily.
Use our genuine part
H000051-1
1
2
3
4
A070305
2
1
3
5
6
4