Operation, Indicator lamp, Indicator lamp warning lamp emergency stop lamp – MMD Equipment 185S-6C1 User Manual
Page 21

4. Operation
4-3
4.1.2
Indicator lamp
Turn the starter switch to “ON” position. Then the lamp will go on.
Item Contents Measures
Monitor
GLOW
Press starter switch “ON” and
the lamp goes on and after pre-
heating is finished, the lamp will
be off.
AUTO IDLE
AUTO IDLE Switch “ON” and
then lamp goes on.
When some little trouble occurs during operation, the lamp will go on.
When the warning lamp goes on, take appropriate measures to recover the situation swiftly.
Item Contents Measures
Monitor
CHARGE
Lamp goes on when alternator is
not charging.
Check wiring.
Check alterna-
tor.
COMP.
AIR FILTER
ENG.
AIR FILTER
Lamp goes on when air filter gets
clogged and suction resistance in-
creases.
Actuating resistance is more than
6.2kPa.
Clean
Replace
The compressor stops when the emergency stop lamp goes on.
Be sure to follow the measures shown below before starting the unit again.
Item Contents
Measures
Monitor
LOW FUEL
LEVEL
When fuel level in fuel tank drops
and it becomes necessary to
replenish fuel, the lamp goes on.
See
“Troubleshooting”
FUEL FILTER
DRAIN
When fuel filter gets clogged with
condensate inside,the lamp goes on. Drain condensate
DISCHRGE
TEMP.
Lamp goes on when the air tem-
perature at the outlet of the
air-end reaches the set tem-
perature of 248°F (120°C).
WATER TEMP.
Lamp goes on when coolant tem-
perature reaches 230°F
(110°C).
ENG.
OIL PRESS.
Lamp goes on when engine oil
pressure drops.
The function pressure is below
0.06MPa.
See
“Troubleshooting”
Indicator lamp
Warning lamp
Emergency stop
lamp