Advanced Color Logic Owner’s Manual - Page 40

CAUTION

REMOVE ALL TEST EQUIPMENT FROM THE

ARC VOLTAGE SIDE OF THE SHUNT BOX PRIOR

TO STARTING THE CURRENT CALIBRATION.

Once connected, with the ACL in WELD Mode, press [START/STOP] on the

HHC. The ANA_CAL procedure will initiate and establish an arc within the

tungsten arc gap, then enter Level 1 and the rotor will start rotating.

CAUTION

PROLONGED EXPOSURE TO THE WELDING ARC

MAY RESULT IN INJURY TO THE EYES AND/OR SKIN.

PROTECT ALL PERSONNEL FROM ALL ARC FLASHES.

Unnecessary extended time in each level of calibration,

or performing repeated calibrations will cause all fixturing

(torch, block and cables) to become very hot.

EXPOSURE TO THESE VERY HOT ITEMS

WILL RESULT IN INJURY TO THE SKIN.

USE CAUTION WHEN HANDLING VERY HOT FIXTURING.

Press [NEXT LEVEL/GAS] on the HHC to jump to the next level, thus

changing the current to the next AMP value. This will occur whenever the

[NEXT LEVEL/GAS] button is pressed.

At each DEMAND AMPS (which is that AMPS value in the ANA_CAL

procedure), adjust the ACTUAL AMPS of the welding arc (displayed on the

DMM (mV x 4 = ACTUAL AMPS)) by pressing the UP ARROW or DOWN

ARROW on the HHC, until the ACTUAL AMPS equals that of the DEMAND

AMPS. Each button press is equal to 1/10 A output adjustment.
Once the ACTUAL AMPS are set equal to the DEMAND AMPS, the

FEEDBACK AMPS (displayed just to the right of the AMPS Bar Graph

at the bottom of the monitor screen) must be adjusted to equal that of

the ACTUAL AMPS value. Pressing the % CURRENT SCALE UP or %

CURRENT SCALE DOWN on the HHC accomplishes this. Each button

press is equal to 1/10 A feedback adjustment.

NOTE

Once all the necessary measurements and assessments

have been made for each level, it is HIGHLY ADVISABLE

to change levels and not remain in any one level

for the entire 300.0 seconds.

Record each of the final display values on the data sheet.
Verify that each of the recorded values = DEMAND AMPS ± 2.0 Amps.
Press [START/STOP] on the HHC when complete. Repeat if necessary (read

CAUTION statement for Current Calibration).