Metro C200 Insulated Heated Cabinet User Manual

Page 4

background image

3

With the racks in the inboard position
(18" width), the following pans may be used:

3" Slide Spacing

16 pans — 18"x26"x2

5

/

8

"

32 pans — 12"x18"x2

5

/

8

"

32 pans — 13"x18"x2

5

/

8

"

17 pans — 14"x18"x2

5

/

8

"

Max. or combined pan size: 18"x27"x2

5

/

8

"

Min. pan width: 16"

4

1

/

2

" Slide Spacing

11 pans — 18"x26"x4

1

/

8

"

22 pans — 12"x18"x4

1

/

8

"

22 pans — 13"x18"x4

1

/

8

"

22 pans — 14"x18"x4

1

/

8

"

Max. or combined pan size: 18"x27"x4

1

/

8

"

Min. pan width: 18"

With the racks in the outboard position
(20" width), the following pans may be used:

3" Slide Spacing

17 pans — 15"x20"x2

5

/

8

"

34 pans — 10

7

/

8

"x19

3

/

4

"x2

5

/

8

"

34 pans — 11

1

/

8

"x20"x2

5

/

8

"

17 pans — 20"x20"x2

5

/

8

"

16 pans — 20"x22"x2

5

/

8

"

32 pans — 12"x20"x2

5

/

8

"

17 pans — 20"x24"x2

5

/

8

"

Max. or combined pan size: 20"x27"x2

5

/

8

"

Min. pan width: 16"

4

1

/

2

" Slide Spacing

11 pans — 15"x20"x4

1

/

8

"

22 pans — 10

7

/

8

"x19

3

/

4

"X4

1

/

8

"

22 pans — 11

1

/

8

"x20"x4

1

/

8

"

11 pans — 20"x20"x4

1

/

8

"

11 pans — 20"x22"x4

1

/

8

"

22 pans — 12"x20"x4

1

/

8

"

11 pans — 20"x24"x4

1

/

8

"

Max. or combined pan size: 20"x27"x4

1

/

8

"

Min. pan width: 18"

C. HOLDING MODULE

Equipped with a holding module, your

cabinet

is designed to maintain the temperature of HOT
prepared foods.

The holding module is

equipped with a thermostatically controlled
heater, a blower for air circulation and a water
pan. A POWER switch is provided with a red
light to indicate when the unit is switched ON.
A TEMPERATURE thermostat and its yellow
indicator light are also provided along with a
thermometer.

A three-wire grounded lead cord is supplied
fixed to the module.

1. With POWER switch OFF, plug lead cord into

a standard grounded 20-amp, 125-VAC
receptacle.

2. To introduce limited humidity, fill the 1

1

/

2

-quart

capacity water pan to

1

/

2

" from top with HOT

clean tap water. During operation, check
water level every 3 hours and refill as
necessary. The unit may be operated without
water if humidity is not desired.

Above the water pan is an adjustable vent.
By rotating the vent open even more humidity
can be introduced into the cabinet.

3. Snap POWER switch to ON. The red light will

now glow as will the yellow indicator light,
and the blower will begin circulating air.

4. Turn the TEMPERATURE thermostat to

setting 10.

5. After allowing the cabinet to PREHEAT FOR

APPROXIMATELY 45 MINUTES, reduce the
thermostat setting to 8. In a room of average
temperature (72

°

F), this should provide

150

°

-170

°

F. Adjustments to the temperature

may be made as necessary.

NOTE: The red light will glow as soon as the
POWER switch is switched ON and will
continue to glow until switched OFF. The
yellow indicator light will go on and off as the
thermostat cycles the heat element. The
blower will operate as long as the POWER
switch is ON. If the yellow light is not
illuminated, this indicates that the cabinet has
achieved the preset TEMPERATURE level,
NOT that the unit has been switched OFF.

It is not necessary at the end of the operating
day to disrupt the TEMPERATURE setting in
order to turn the unit OFF. By switching the
POWER switch to OFF, the unit is no longer
operating. By switching the POWER switch to
ON when resuming operations, the cabinet
will attain the preset level.