Hsc509, Hsc509 features – Meinberg HSC509 User Manual
Page 8
![background image](https://www.manualsdir.com/files/798059/content/doc008.png)
8
HSC509
The radio remote clock HSC509 has been designed for applications where two
independent serial interfaces and up to four free programmable relay outputs are
needed. The clock also offers the possibility to control slave clocks via the integrated
slave clock drivers. The clock is equipped with an internal power supply.
NETZ
MOD.
FLED
FREIL.
CLR/ACK
NEXT
INC
MENU
HSC509
Frontview HSC509
HSC509 Features
The radio clock HSC509 offers a number of functions and is mounted in a plastic
housing for wall-mounting. It provides four free programmable relay outputs, a slave
clock master with two slave lines and two independent serial interfaces. The 100mm x
160mm wide frontpanel includes a 4 x 16 character LC display, four control LEDs and
four keys. The external ferrite antenna is connected to the receiver via a 50 ohm
coaxial cable. If the distance between antenna and receiver exceeds 100m an amplifier
may be necessary.
The HSC509 contains a new flash EPROM with bootstrap loader that allows the
user to upload a new firmware via the serial interface without opening the housing of
the clock.