Operation

NETZ

MOD.

FLED

FREIL.

CLR/ACK

NEXT

INC

MENU

HSC509

Frontpanel HSC509

MENU Key

This key lets the user step through several display menus showing specific data.

CLR/ACK Key

This key has to be used when parameters are to be modified. When this key is pressed
the parameters that have been edited are saved in the battery buffered memory. If the
menu is left without pressing CLR/ACK all changes are discarded. If the current menu
just displays data (cursor not visible) pressing this key switches to a submenu (if
available).

NEXT Key

When editing parameters (LCD cursor is visible) this key moves the cursor to the next
digit rsp. to the next parameter to be edited.

INC Key

When editing parameters this key increments the digit or letter at the cursor position.

INC Key together with CLR/ACK Key

When pressing CLR/ACK while INC is beeing pressed the currently displayed data is
cleared and the cursor jumps to the first position.