beautypg.com

Setup initial time, Init user parms, Init gps parms – Meinberg GPS170LCD-MP User Manual

Page 33

background image

33

SETUP INITIAL TIME

If the receiver´s on-board real time clock keeps a wrong time the receiver is unable to
compute the satellites´ correct elevation angles and dopplers. This submenu enables
the user to change the receiver´s system time for initialization. After the receiver has
locked, its real time clock will be adjusted using the information from the satellites.

SETUP: INITIAL TIME

SET INITIAL TIME MESZ
Date: DD.MM.YYYY Time: 12:00:00

INIT USER PARMS

This menu lets the user set all parameters back to the default settings. The user has to
acknowledge this menu again before the initialisation starts.

SETUP: INIT USER PARMS

Are you sure ? Press ...
INC => YES MENU => NO

INIT GPS PARMS

This menu lets the user initialize all GPS datas, i.e. all saved satellite datas will be
cleared. The user has to acknowledge this menu again before the initialisation starts.
The system starts operating in the COLD BOOT mode and seeks for a satellite to read
its actual parameters.

SETUP: INIT GPS PARMS

Are you sure ? Press ...
INC => YES MENU => NO