Meinberg GPS170LCD-MP User Manual
Page 20
20
"..............(drft)"
The frequency is generated and the phase was already syn-
chronous to the pulse output P_SEC, but in the moment the
phase can´t be controlled or adjusted because no satellite is
received now.
If the NEXT key is pressed one time from the root menu a submenu is displayed
showing the receiver´s software revision:
Meinberg GPS170 S/N: 0290100xxx70
REV:1.xx LCD_2
If the NEXT key is pressed for second time a submenu is displayed showing other
receiver´s infos
RECEIVER INFO: PROUT: 3 NCOM: 4
FF_OUT: n/a OCXO_LQ 02E3003
Meaning of the abbreviations and adjusted standard value:
"PROUT: 0"
programmable pulse
standard: 0 (not available)
optional: 3 (until three prog. pulse)
"NCOM: 2"
serial interface
standard: 2 (COM0 and COM1)
optional: 4 (COM0 - 3)
"FF_OUT"
frequency synthesizer for fixed frequencies
standard: N/A (not available)
"OCXO_LQ"
used oscillator (see Oscillatorspecifications)
"002E3003"
EPLD Version (checksum)