Setup enable outputs, Setup time zone – Meinberg GPS170LCD-MP User Manual
Page 24
![background image](https://www.manualsdir.com/files/798032/content/doc024.png)
24
SETUP ENABLE OUTPUTS
This menu lets the user configure at which time after power up the serial ports, pulse
outputs, and frequency synthesizer output are to be enabled. Outputs which are shown
to be enabled always will be enabled immediately after power-up. Outputs which are
shown to be enabled if sync will be enabled after the receiver has decoded the signals
from the satellites and has checked or corrected its on-board clock. The default setting
for all outputs is if sync.
SETUP: ENABLE OUTPUTS
Serial: if sync Pulses: if sync
Synth: if sync
SETUP TIME ZONE
This menu lets the user enter the names of the local time zone with daylight saving
disabled and enabled, together with the zones´ time offsets from UTC. The left part of
the display shows the zone and offset if daylight saving is off whereas the right part
shows name and offset if daylight saving is on. These parameters are used to convert
UTC to local time, e.g. MEZ = UTC + 1h and MESZ = UTC + 2h for central europe.
The range of date daylight saving comes in effect can be entered using the next two
topics of the setup menu.
SETUP: TIME ZONE
DAYLIGHT SAVING OFF: !MEZ ! +01:00h
DAYLIGHT SAVING ON : !MESZ ! +02:00h