System monitoring, Environmental, Mechanical – Measurement Computing STLITE-PCI-8x User Manual
Page 20

16
System Monitoring
System monitoring features can be accessed via VB/C++ example programs and DLL provided with the
product.
A/D Converter
TLV2548, 8-channel, 12-bits. One per STLITE-PCI-8T,
two per STLITE-PCI-8T+.
Voltage Monitoring:
PCI voltages; +5V, +3.3V, +12V, and –12V
Absolute Accuracy: ±2%
Temperature Monitoring:
Sensor
Semiconductor type, Range: -55 to 150°C,
Resolution: 0.03°C
Absolute Accuracy: ±2.5°C max, ±0.9°C typ over entire
Range
Backplane
One sensor located in the center of the Backplane
Slots (only available on STLITE-PCI-
8T+)
One sensor positioned above each slot on a circuit card
mounted inside the cover
Fan Monitoring:
Current
15mA < I < 350mA, 6% absolute accuracy. Fan currents
of 15mA or less indicate an OFF or OPEN condition.
Environmental
Operating Temperature Range
0 to 50°C
Storage Temperature Range
−
20 to 65°C
Operating Humidity
0 to 90% non-condensing
Storage Humidity
0 to 95% non-condensing
Mechanical
Enclosure
Portable Table-top design
Dimensions
15.25”L x 8.00”W x 6.33”H
Weight
8 lbs.
Construction
0.080” Aluminum case/cover. 0.040” Steel faceplate.
Cooling
Power supply fan plus one DC fan, 30 CFM typ