4) configure the system – Measurement Computing Personal Daq rev.6.0 Quick Start User Manual

Page 8

background image

6

p/n

491-0940,

Rev

6.0

878495

Personal Daq Quick Start

(4) Configure the System

This step pertains to the configuration of channels and acquisition parameters through Personal DaqView
software. To configure a set of parameters, use the appropriate toolbar button (or the View pull-down
menu) to open the applicable window. Clicking on the Configure Channel Settings button (9) brings up
the Channel Configuration Window.

Main Control Window

Channel Configuration Window, with Analog Input Spreadsheet Selected

Button

Function

1

Open Configuration File

Opens a selected configuration file.

2

Save Configuration File

Saves the current configuration file to disk.

3

Select Active Device

Provides a means of selecting active devices from the Personal Daq system.

4

Arm Trigger for Disk
Recording

Arms the trigger and stores acquisition data to a designated disk file. If Auto Rearm is
selected, clicking this button puts Auto rearm in effect. This button, is also used to
disarm the data acquisition.

5

Manual Trigger

Used to trigger the device when the mode of trigger is set to “Manual.” Note that the
Manual Trigger button can not be depressed until after the trigger is armed, for
example, by first pressing button 4.

6

Update Digital Outputs

Updates digital outputs for all digital channels that are selected to “output state.” also
see Digital Input/Output Spreadsheet, in chapter 4 of the user’s manual.

Digital I/O does not apply to Personal Daq/54

.

7 Configure

Data

Destination

Accesses the Configure Data Destination window. Note that this window provides a
means of selecting sequential destinations through an auto rearm feature.

8 Configure

Acquisition

Accesses

the Configure Acquisition window.

9 Configure

Channel

Settings

Brings up the Channel Configuration window. From this window you can configure
channels for Analog Input, Frequency/Pulse Input, and Digital Input/Output channels,
depending on which tab is selected.

10

Update All Indicators

Starts all on-screen indicators with a display of up-to-date data. Has no affect on the
recording of data to disk. Auto Rearm, even if selected, will not occur when using this
control. This button is also used to pause all indicators.

11

Display Scrolling Charts

Displays data graphically in a scrolling chart.

12

Display Bar Meters

Displays data in a bar graph format.

13

Display Analog Meters

Displays data displayed in a dial-gage format.

14

Display Digital Meters

Displays data in a digital meter format.

15

View Data

Launches an independent post-data acquisition program such as eZ-PostView, if
installed. The install CD includes a .pdf version of the eZ-PostView document.

16 Enable

Readings

Column

Activates the Channel Configuration Window’s reading column. Does not affect the
recording of data to disk.

17 Disable

Readings

Column

Stops the Channel Configuration Window’s reading column. Does not affect the
recording of data to disk.