3 - using iotech labview substitution vis, Overview, 3 – using iotech labview substitution vis …… 3-1 – Measurement Computing LabVIEW Rev.3.0 User Manual
Page 11: Using iotech labview substitution vis 3

IOtech LabVIEW Substitution VIs
10-03-02
3-1
Using IOtech LabVIEW Substitution VIs
3
Overview
The IOtech Data Acquisition sub-directory contains folders for the various types of Virtual Instruments.
Each folder contains pertinent sample programs. The folders are designated:
• Analog Input
• Analog Output
• Counter
• Digital IO
In addition to these four VI folders, the sub-directory also contains a Documentation folder. The folders
can be accessed from the Windows Start Menu, under the LabVIEW directory (located under
DaqXSoftware).
IOtech LabVIEW Substitution VIs were designed to emulate National Instruments VIs. The substitutions
can be made in applications where an IOtech DaqBoard/2000 Series board is being used to replace a
NI-DAQ “E” Series device, a PC-LPM-16, or an AT-MIO-16 “H” or “L” Series board; however, for the
AT-MIO-16 L, the x500 gain-setting will not be supported. NI devices can typically be replaced with little
effort. An example follows shortly.
Supported VIs
Easy VIs
Intermediate VIs
Advanced VIs
AI Sample Channel
AI Sample Channels
AI Acquire Waveform
AI Acquire Waveforms
AO Update Channel
AO Update Channels
AO Generate Waveform
AO Generate Waveforms
Read from Digital Line
Read from Digital Port
Write to Digital Line
Write to Digital Port
Count Events or Time
Measure Pulse Width or
Period
AI Clear
AI Config
AI Continuous Scan
AI Read One Scan
AI Read
AI Single Scan
AI Start
AI Waveform Scan
AO Clear
AO Config
AO Continuous Gen
AO Start
AO Wait
AO Waveform Gen
AO Write One Update
AO Write
DIO Clear
DIO Config
DIO Read
DIO Single Read_Write
DIO Start
DIO Wait
DIO Write
Adjacent Counters
Counter Read
Counter Start
Counter Stop
Event or Time Counter Config
Pulse Width or Period Meas
Config
Wait+ (ms)
AI Buffer Config
AI Buffer Read
AI Clock Config
AI Control
AI Group Config
AI Hardware Config
AI Parameter
AI SingleScan
AI Trigger Config
AO Buffer Config
AO Buffer Write
AO Clock Config
AO Control
AO Group Config
AO Hardware Config
AO Parameter
AO Single Update
AO Trigger and Gate Config
Digital Buffer Config
Digital Buffer Control
Digital Buffer Read
Digital Clock Config
Digital Group Config
Digital Single Read
Digital Single Write
Digital Trigger Config
DIO Port Config
DIO Port Read
DIO Port Write
CTR Control
CTR Group Config
CTR Hardware Config
CTR Mode Config
Channel To Index