Relay specifications
Table 1. Relay Output specifications
Number
8
Contact configuration
8 FORM C (SPDT) NO, NC and Common available at connector
.
Contact rating
6 amperes (A) @ 240 volts AC (VAC) or 28 volts DC (VDC) resistive (see connector rating
below)
Contact resistance
100 milliohms (mΩ) max
Operate time
10 milliseconds (ms) max
Release time
10 milliseconds max
Vibration
10 to 55 hertz (Hz) (Dual amplitude 1.5 millimeters (mm))
Shock
10 G (11 ms)
Dielectric isolation
500 V (1 minute)
Life expectancy
10 million mechanical operations, min
Power on RESET state
Not energized. NC in contact to Common.
Isolated inputs
Table 2. Isolated input specifications
Number
8
Isolation
500 volts ( V)
Resistance
1.6k ohms (Ω) min.
Input high:
+5.0 VDC min or –5.0 VDC min
Input low:
+1.5 VDC max. or –1.5 VDC max.
DC
Input range:
30 VDC max
Input high:
6.0 V
rms
min (50-1000 Hz)
Voltage range
AC (with filter)
Input low:
1.5 V
rms
max (50-1000 Hz)
w/o filter
20 µs
Response
w/ filter
5 ms
Time constant
5 ms (200 Hz)
Filter control
Software programmable at each input.
Filters
Power-up /reset
Filters off