beautypg.com

Measurement Computing PC104-DAS08 User Manual

Page 7

background image

Table 1-1. PC I/O Addresses

SERIAL PORT

3F8-3FF

EGA

2B0-2BF

FLOPPY DISK

3F0-3F7

PARALLEL PRINTER

270-27F

SERIAL PORT

3E8-3EF

ALT BUS MOUSE

23C-23F

CGA

3D0-3DF

BUS MOUSE

238-23B

EGA

3C0-3CF

EXPANSION UNIT (XT)

210-21F

PARALLEL PRINTER

3BC-3BF

GAME CONTROL

200-20F

MDA

3B0-3BB

HARD DISK (AT)

1F0-1FF

SDLC

3A0-3AF

80287 NUMERIC CO-P (AT)

0F0-0FF

SDLC

380-38F

8237 #2 (AT)

0C0-0DF

PARALLEL PRINTER

378-37F

NMI MASK (XT)

0A0-0AF

HARD DISK (XT)

320-32F

8259 PIC #2 (AT)

0A0-0A1

PROTOTYPE CARD

310-31F

DMA PAGE REGISTERS

080-08F

PROTOTYPE CARD

300-30F

CMOS RAM & NMI MASK
(AT)

070-071

SERIAL PORT

2F8-2FF

8742 CONTROLLER (AT)

060-064

SERIAL PORT

2E8-2EF

8255 PPI (XT)

060-063

GPIB (AT)

2E0-2E7

8253 TIMER

040-043

EGA

2D0-2DF

8259 PIC #1

020-021

EGA

2C0-2CF

8237 DMA #1

000-00F

FUNCTION

HEX

RANGE

FUNCTION

HEX

RANGE

The BASE switches can be set for address in the range of 000-3F8 so it should not be
hard to find a free address area. If you are not using IBM prototyping cards,
300-31F HEX are free to use.

Address not specifically listed, such as 390-39F, are free.

1.2 .2 INTERRUPT LEVEL SELECT

The interrupt jumper need only be set if the software you are using requires it. If you
do set the interrupt jumper, please check your PC's current configuration for
interrupt conflicts.

Do not use IR2 in PC/AT class machines (or higher).

There is a jumper block on the PC104-DAS08 located just above the PC bus
interface (see Figure 1-1). The factory default setting is that no interrupt level is set
(the jumper is in the 'X' position). See Figure 1-3.

If you need to pace conversions through hardware (either the on-board pacer or an
external clock), move this jumper to one of the other positions (see Table 1-2).