Specifications, Digital input / output, Power consumption – Measurement Computing CIO-DIO24 User Manual
Page 17: Environmental

Chapter 5
Specifications
Typical for 25 °C unless otherwise specified.
Specifications in italic text are guaranteed by design.
Digital Input / Output
Table 1. Digital input/output specifications
Digital type
82C55
Configuration
2 banks of 8, 2 banks of 4, programmable by bank as input or output
Number of channels
24 I/O
Output high
3.0 volts min @ -2.5 mA
Output low
0.4 volts max @ 2.5 mA
Input high
2.0 volts min, 5.5 volts absolute max
Input low
0.8 volts max, -0.5 volts absolute min
Power-up / reset state
Input mode (high impedance)
Interrupts
2 through 7, jumper selectable
Interrupt enable
External (IR Enable), logic low enabled (disabled by default via internal
10k resistor to +5V)
Interrupt sources
External (IR Input), rising edge
Miscellaneous
Locations provided for installation of pull-up or pull-down resistors.
Power consumption
Table 2. Power consumption specifications
Parameter Specification
+5V
170 mA typical, 270 mA max
Environmental
Table 3. Environmental specifications
Operating temperature range
0 to 70 °C
Storage temperature range
-40 to +100 °C
Humidity
0 to 90% non-condensing
17