External clock input, Counter – Measurement Computing BTH-1208LS User Manual
Page 24

BTH-1208LS User's Guide
Specifications
24
Input low voltage threshold
0.98 V typ
0.6 V min
1.5 V max
Input low voltage limit
–0.5 V absolute min
0 V recommended min
External clock input
Table 13. External clock input specifications
Parameter
Specification
Terminal name
AICKI
Terminal type
Input
Input clock rate
50 kHz, max
Clock pulse width
1 µs min
Input type
Schmitt trigger, 47
kΩ pull-down to ground
Schmitt trigger hysteresis
0.76 V typ
0.4 V min
1.2 V max
Input high voltage threshold
1.74 V typ
1.3 V min
2.2 V max
Input high voltage limit
5.5 V absolute max
Input low voltage threshold
0.98 V typ
0.6 V min
1.5 V max
Input low voltage limit
–0.5 V absolute min
0 V recommended min
Counter
Table 14. Counter specifications
Parameter
Specification
Pin name
CTR
Counter type
Event counter
Number of channels
1
Input type
Schmitt trigger, 47 kΩ pull-down to ground, rising edge triggered
Input source
CTR screw terminal
Resolution
32 bits
Maximum input frequency
1 MHz
High pulse width
500 ns min
Low pulse width
500 ns min
Schmitt trigger hysteresis
0.76 V typ
0.4 V min
1.2 V max
Input high voltage threshold
1.74 V typ
1.3 V min
2.2 V max
Input high voltage limit
5.5 V absolute max
Input low voltage threshold
0.98 V typ
0.6 V min
1.5 V max