Page 14

Specifications

ADAT O

PTICAL

I/O

Number / Type Two inputs and two outputs, compatible with Alesis ADAT Type I and Type II

Optical Digital Interface Protocol, up to 24-bit data

Channels 16 @ 44.1kHz 48 kHz sample rates

8 @ 88.2 kHz and 96 kHz sample rates, S/MUX enabled
4 @ 176.4 kHz and 192 kHz sample rates, SMUX enabled

Input Receiver Fast-locking phase-locked loop with 30 kHz to 55 kHz lock range

ADAT S

YNCHRONIZATION

I/O

Number / Type One 9-pin Sync In port compatible with Alesis Synchronization Protocol

Signals Time code (sample count), word clock, and MIDI control data

Sample Accurate

Methods

ASIO Positioning Protocol and hardware-based SMPTE frame address matching
logic (Cue Point).

MTC Time code to MTC conversion

MIDI MIDI port transfers serial input control data

C

LOCK

S

YNCHRONIZATION

Clock Sources Host card (LynxTWO or L22), Optical In 1, Optical In 2, ADAT Sync In

Modes Master mode: utilizes LynxTWO or L22 low-jitter sample clock to drive external

ADAT devices
Slave mode: word clock derived from external ADAT device

A

RCHITECTURE

Core FPGA-based core. Support for field upgrades of firmware.

Audio Devices Host Card is visible to applications as eight stereo record devices corresponding to

ADAT optical inputs 1 – 16 and eight stereo play devices corresponding to ADAT
optical outputs 1 – 16.

Routing/Mixing Integrates with host card’s digital mixer to allow independent routing of ADAT I/O

with host card analog and digital I/O.

C

ONNECTIONS

I/O Ports (4) Bracket-mounted TOSLINK connectors. (1) 9-pin female D-sub connector.

Other LStream interface headers

G

ENERAL

Host Interface Lynx proprietary LStream

™ Interface: 24.5 Mbps bi-directional

Requirements One available bracket position (PCI slot not required), Host card: LynxTWO or L22

Size 3.0” H X 5.0” W X 0.75” D

EMI Certifications FCC and CE