LSC Lighting NEXUS User Manual
Page 15

NEXUS
Applications
Operator Manual V1.01
© 2011 LSC Lighting Systems (Aust) Pty. Ltd
Page 9
Back-up switching of Lighting Controllers. Main and backup lighting controllers have
ArtNet or sACN outputs on different universes. Nexus 1 receives both ArtNet or sACN
universes and the DMX output port is configured for Priority Mode which will auto
changeover to secondary on loss of the primary universe.
DMX to ArtNet or sACN converter. Nexus converts the DMX to the ArtNet or sACN
universe that you specify. ArtNet or sACN is distributed throughout the facility using low
cost Ethernet infrastructure. Multiple Nexus 1 units provide DMX to operate lighting
equipment.
Lighting
Controller
ArtNet or sACN
Universe 0.0
Network
device
supplying
PoE to Nexus
Ethernet
Nexus 1
Pri. U 0.0
Sec. U 0.1
Ethernet
DMX Devices
DMX
DMX Devices
Backup
Controller
ArtNet or sACN
Universe 0.1
Ethernet
NexLan
Computer
Lighting
Controller
DMX O/P
Network
device
supplying
PoE to Nexus
DMX
Nexus 1
Ethernet
DMX Devices
Ethernet
Nexus 1
Nexus 1
Nexus 1
DMX Devices
DMX Devices
DMX
NexLan
Computer