SunScan User Manual v 1.05

Menus and Screens

••••

31

Settings

Titles

Title

≤≤≤≤

40 chars.

Title name is stored in the data file heading, and is displayed on
the Title screen.

(contd.)

Group

≤≤≤≤

40 chars.

Name for a group of readings. A new name (or setting change)
starts a new group.

Site

Site Name

≤≤≤≤

40 chars.

Name of your measurement site.

Latitude

-90

°°°°

to +90

°°°°

Latitude of your measurement site. Use negative numbers south
of equator.

Longitude

-180

°°°°

to

+180

°°°°

Longitude of your measurement site. Use negative numbers east
of Greenwich meridian.

Time &
Date

Local time

Set clock to the time at the measurement site.

Date

Today’s date.

Local time
is GMT

-12.0 to +13.0

Offset of local time zone from GMT. Remember to include
provision for any local “Summer” time etc.

Display

Display:

LAI

Display:

PAR

Display:

All

Same as for PAR, but individual readings stored to the data file.

'Sample'
name

≤≤≤≤

6 chars.

Change name if ‘Sample’ is not appropriate.

'Plot' name

≤≤≤≤

6 chars.

Change name if ‘Plot’ is not appropriate.

Utils

Calibrate

Restore
Factory
Calibration

Restores each photodiode's calibration coefficient as determined
by Delta-T.

Recalibrate
SunScan

Calculate and reset the individual photodiode calibration
coefficients using the Beam Fraction sensor as a reference.

Autolog
(setup
screen)

SunScan will operate unattended in whatever mode has been set-
up. Complete all the screen entries then press Enter to initiate
Autolog process.

Start

Date, time

Type in start date and time. These can be in the past 24 hours to
allow alignment with particular periods.

Stop

Date, time

Type in date and time to finish. Must be in the future.

Read
interval

hh:mm:ss

Type in the sampling interval. Every reading is stored.
Minimum 00:00:01, maximum 23:59:59.

Average
interval

hh:mm:ss

Stores averages at the specified interval. Should be a multiple of
the read interval. Zero gives no averages.

Ignore
nighttime?

yes, no

Yes: readings are not taken at night.
No: readings are continuous.

(progress
screen)

Sleep, (or
Off)

Blanks the screen. This is the usual condition. Press On/Esc to re-
awaken it.

Cancel

Stops the Autolog process on demand.

Comms
Test

Dumb terminal mode. Factory setup use only.

About

Displays Psion SunData s/w version, and the battery voltage and
status for both the SunScan probe and Workabout.

Solar Zenith

Incident PAR
Transmitted PAR

Photodiode spread

Beam Fraction

Leaf Area Index

Transmitted PAR

Photodiode spread

Incident total PAR

Incident diffuse PAR