beautypg.com

Delta Electronics Single Mode SFP Transceiver LCP-1250B4QDRx User Manual

Page 12

background image

DELTA ELECTRONICS, INC.

12 2008/1/23

Rev. 6G

www.deltaww.com

6)

State/ Control Bits

Byte

Bit

Name

Description

110

7

Tx Disable State

Digital state of the Tx disable input pin

110

6

Soft Tx Disable

Read/ Write bit that allow software disable of laser

110 5

Reserved

110

4

Rate Select tate

NA

110

3

Soft Rate Select

NA

110

2

Tx Fault

Digital state of the Tx fault output pin

110 1

LOS

Digital

state

of the LOS output pin.

110

0

Data_Ready_Bar

NA

7)

Optional Set of Alarm and Warning

Byte

Bit

Name

Description

112

7

Temp High Alarm

Set when internal temperature exceeds high alarm level

112

6

Temp Low Alarm

Set when internal temperature is below low alarm level

112

5

Vcc High Alarm

Set when internal supply voltage exceeds high alarm level

112

4

Vcc Low Alarm

Set when internal supply voltage is below low alarm level

112

3

Tx Bias High Alarm

Set when Tx Bias current exceeds high alarm level

112

2

Tx Bias Low Alarm

Set when Tx Bias current is below low alarm level

112

1

Tx Power High Alarm

Set when Tx output power exceeds high alarm level

112

0

Tx Power Low Alarm

Set when Tx output power is below low alarm level

113

7

Rx Power High Alarm

Set when received power exceeds high alarm level

113

6

Rx Power Low Alarm

Set when received power is below low alarm level

113

5-0

Reserved

116

7

Temp High Warning

Set when internal temperature exceeds high warning level

116

6

Temp Low Warning

Set when internal temperature is below low warning level

116

5

Vcc High Warning

Set when internal supply voltage exceeds high warning level

116

4

Vcc Low Warning

Set when internal supply voltage is below low warning level

116

3

Tx Bias High Warning

Set when Tx Bias current exceeds high warning level

116

2

Tx Bias Low Warning

Set when Tx Bias current is below low warning level

116

1

Tx Power High Warning

Set when Tx output power exceeds high warning level

116

0

Tx Power Low Warning

Set when Tx output power is below low warning level

117

7

Rx Power High Warning

Set when received power exceeds high warning level

117

6

Rx Power Low Warning

Set when received power is below low warning level

117

5-0

Reserved

Digital Diagnostic Monitor Accuracy

Parameter

Typical Value

Note

Transceiver Temperature

± 3℃

1

Power Supply Voltage

± 3%

2

TX Bias Current

± 10%

TX Optical Power

± 1.5dB

RX Optical Power

± 3dB

Notes:

1) Temperature is measured internal to the transceiver.

2)

Voltage is measured internal to the transceiver.