7. SERVICE AND OPERATION DISTURBANCES

The amount of use and working environment should be taken into consideration when planning

the frequency of maintenance of PROMIG. Careful use and preventive maintenance will help to

ensure trouble-free operation.
Following maintenance operations should be carried out at least every six months:

Check:

– Feed roll grooves. Excessive wear of grooves causes

wire feed problems.

– Wire guide tubes. Badly worn feed rolls and wire guide

tubes should be discarded.

– Wire guide tube in the gun should be set as near the feed

rolls as possible and the wire must follow a straight line

from the end of the tube to the groove of the feed roll.

– Reel brake adjustment.
– Electrical connections:
* Oxidized couplings must be cleaned
* Loose couplings must be tightened

Clean dust and dirt from the equipment.

When using compressed air, always protect your eyes with proper eye protection.

In case of problems contact your KEMPPI dealer.

8. DISPOSAL OF THE MACHINE

Do not dispose of electrical equipment together with normal waste!
In observance of European Directive 2002/96/EC on Waste Electrical and Electronic

Equipment and its implementation in accordance with national law, electrical equipment

that has reached the end of its life must be collected separately and returned to an

environmentally compatible recycling facility. As the owner of the equipment, you should

get information on approved collection systems from our local representative.
By applying this European Directive you will improve the environment and human

health!