Kemppi Promig 520R User Manual
Page 18
18 – PROMIG 520R, 120R / 0544
© KEMPPI OY
Welding method selecting switch S31
No function: always two-sequence procedure
MIG welding with two-sequence procedure
1. switch pressed: welding starts
2. switch open: welding stops
Control mode selecting switch S32
Local control: Control potentiometers R31 and R32
Remote control: Voltage and wire feed speed set values from robot controller
(gun control = remote position)
Local controls R31, R32
Wire feed speed potentiometer
MIG/MAG: Local control for wire feed speed 0...18 m/min or 0...25 m/min
SYNERGIC MIG: Power control
SYNERGIC PULSED MIG: Power control
Voltage / arc length potentiometer
MIG local control for PRO power source welding voltage, 10 V...max MIG voltage of power
source
SYNERGIC MIG: Fine control for arc length, shows voltage which has been programmed in
proportion to wire feed value. Voltage control range depends on wire feed value.
SYNERGIG PULSED MIG: Fine control for arc length -9...0...9
Control of welding dynamics R33
When you adjust welding dynamics, the adjustment value -9...0...9 is shown in
display V, which otherwise shows set value / welding voltage. Value of dynamics
is shown in display for approx. 3 s after adjustment.