14 – PROMIG 520R, 120R / 0544

© KEMPPI OY

MIG basic operations

Welding method selection (S21): no function
Control mode selection (S22): local, remote by robot controller
Local controls: wire feed speed (R21), welding voltage (R22)
Controls for MIG welding dynamics (R23)
Digital displays: wire feed speed (P21), current (P22), voltage (P23)
Retrieval of last weld values (S23)

SELECTO operations

SELECTO mode switch S24
OFF: Normal MIG/MAG welding
ON: Welding with memory stored values (5 channels)
SET: Welding parameters selection and storage SAVE (S25), for selected channel CHANNEL

1...5 (S26).

Welding method selecting switch S21

No function: always two-sequence procedure
MIG/MAG welding with two-sequence procedure
1. start on: welding starts
2. start off: welding stops

Control mode selecting switch S22

Local control: Control potentiometers R21 and R22 on panel are operational.
Remote control: Voltage and wire feed speed set values controlled by robot

controller
(Switch center = remote position)

Local controls R21, R22

Wire feed speed potentiometer

SELECTO OFF: Local control for wire feed speed 0...18

m/min or 0...25 m/min
SELECTO ON: No operation
SELECTO SET: Local control for wire feed speed 0...18

m/min or 0...25 m/min

Voltage potentiometer

SELECTO OFF: Local control for voltage of PRO power

source, 10 V...max. MIG voltage of power source
SELECTO ON: No operation
SELECTO SET: Local control for voltage of PRO power

source, 10 V...max. MIG voltage of power source