Command set – Delta LTL2000S User Manual
Page 38
DELTA
LTL2000S(Q) Retroreflectometer
34
Command set
Command
Parameter
Response
Meaning
Rl Status Code 0 00000000
2002 Aug 12 13:53:19
LTL2000SQ v1.0 s/n:n
Rl status code
Time for Rl measurement
Instrument Id
OTn None
59
180
Off Timer = 300 sec.
Off Func: Off
Off Timer: = 180 sec.
Automatic turn off time when not in use. Range 60 to
600 sec. Disable for time < 60 sec
PV
None
V_PMT = 644 Volt
Voltage on PMT
QCn
None
123
QdF: 0.1366
Cal Qd? [Y/N]
Cal Qd!
Qd Factor = 0.7564
Qd Normal = 123
Query Qd calc factor
Calibrate Qd to 123 Y/N response to start
Calibrating Qd
Calculated calc factor
New active Qd normal
QEn None
F
T
Qd On
Qd Off
Qd On
Query Qd function
Set Qd function Off
Set Qd function On
RCn None
123
RlF: 2.038
Cal Rl [Y/N]
Cal Rl
Rl Factor = 2.032
Rl Normal = 123
Query Rl Calc factor
Calibrate Rl to 123 Y/N response to start
Calibrating Rl
Calculated calc factor
New active Rl normal
REn None
F
T
Rl On
Rl Off
Rl On
Querry Rl function
Set Rl function Off
Set Rl function On
RZ None Zero
Adjust?
[Y/N]
Zero Rl
*** Zero Reading ***
Lamp On: 12
Lamp Off: 10
New Rl_Sy_Leak: 2
Perform Rl zero adjust with Y/N confirmation
Measuring zero signal
Result from zero reading
Signal with lamp on
Signal with lamp off
New SyLeak signal
SD None
Rl Status Code 0 00000000
Qd Status Code: 0 00000000
Status code and bit pattern
if status not zero then the status code is decoded
SNn None
TEST2
Seq ID: DELTA
Meas in Seq: 3
Seq ID: TEST2
Meas in Seq: 0
Querry Sequence number
Measurements with this ID
Change ID to TEST2
No measurements with this ID
TIn
None
10 02 25
2002 Aug 12 13:59:37
2002 Aug 12 10:02:25
Real time clock Date and Time
New Time (Date unchanged)