1.
Control panel K 60
2.
Main switch (ON/OFF)
3.
Main power indicator light (ON/OFF)
4.
Warning indicator for thermal protection
5.
Welding cable connection, negative pole ( – )
6.
Welding cable connection, positive pole ( + )
7.
Control cable connection
8.
Fuse, 6.3 A, delayed
9.
Control cable connection
10. Robot control connection
11. Wire feeder connection
12. Throughput connection
13. Analogue connection
14. Connection for KempArc Browser or Tandem
2.3
MAIN SWITCH
When you turn the main switch to position I, the main switch indicator light turnes on and the
machine is ready for use.
NOTE!
Always start and stop the machine from the main switch, never use the plug as a switch!
2.4
INDICATOR LIGHTS
Indicator lights display the machine’s operational state. When the green indicator is lit, it
displays that the machine is switched on and is ready for use, and that it is connected to the
mains supply with the power source main switch in position I.
When the orange indicator is lit, it indicates that the thermal protection circuit has been
activated due to high working loads that exceed the rated duty cycle. The cooling fan will
continue to run and cool the machine down. When the light turns off, the machine is again
ready to weld.
2.5
OPERATION OF THE COOLING FAN
KempArc Pulse TCS power sources incorporate two simultaneously operating fans.
• The fan starts momentarily, when you turn the machine on from the main switch.
• The fan will start during welding as the machine reaches operational temperature,
and it will run for 1 to 10 minutes after the welding has stopped, depending on the
welding cycle completed.
2.6
MACHINE ASSEMBLY AND POSITIONING
KempArc Pulse TCS is delivered with a KempCool 40 cooler unit, which also serves as a stand
for the two power sources. The cooler unit delivery package contains the fixing screws and
plates for attaching the power sources on top of the cooler unit.
To assemble the KempArc equipment, do the following:
1.
Attach the fixing plates to the power sources with the screws delivered in the package.
2.
Lift the leading power source onto the cooler unit, and attach the cooler control lead to
the connector on the bottom of the power source.
3.
Fix with four screws on the facing side and the backside.
4.
Lift the other power source onto the cooler unit and fix with screws.
NOTE!
Remember to attach first the fixing plates to the power sources, then lift the power sources
on the cooler unit.
NOTE!
When starting to use the machine, do the following configuration settings in the K 60
control panel menu:
- Set Water Cooling mode to AUTO in the leading machine that is connected to the cooler.
- Set the Water Cooling mode to OFF in the other machine.
5
KempA
rc P
ulse
TCS / © Kemppi O
y / 1204