Kemppi Pulse TCS User Manual
Page 20

EN
3.4.3 Welding functions
OTHER PROCESSES
(In Edit Channel menu 3/6)
HotStart
ON, OFF or USER
Factory setting is USER =>
USER can freely choose is the
HotStart ON or OFF
HOTStartLevel
-50 ... +100 %
1 % steps. Factory setting 40 %
Hot 2T Time
0 – 9.9 s
0.1 s steps. Factory setting 1.2 s
CraterFill
ON, OFF, USER
Factory setting is USER =>
USER can freely choose is the
CraterFill ON or OFF
CraterStart
10 – 250 %
Factory setting is 100%
Set the level of the curve where the crater
filling will start
CraterFillEnd
10 – 250 %
lower than start
1 % steps. Factory setting 30% Set the level of the curve where the crater
filling will end.
CraterTime
0.0 – 10.0 s
0.1 s steps. Factory setting 1.0 s CrateFill Slope Time
Creep Start
10 – 99 %
1% steps. OFF, CURVE
(OFF = 100%)
Factory setting is CURVE (Creep Start value
comes from Welding Curve).
StartPower
-9 ... +9
Factory setting is 0
Adjusts arc ignition
WISEROOT / WISETHIN
HotStart
ON, OFF or USER
Factory setting is USER =>
USER can freely choose is the
HotStart ON or OFF
HOTStartLevel
-50 ... +100 %
1 % steps. Factory setting 40 %
Hot 2T Time
0 – 9.9 s
0.1 s steps. Factory setting
1.2 s
CraterFill
ON, OFF, USER
Factory setting is USER =>
USER can freely choose is the
CraterFill ON or OFF
CraterStart
10 – 250 %
Factory setting is 100%
Set the level of the curve where the crater
filling will start.
CraterFillEnd
10 – 250 %
lower than start
1 % steps. Factory setting 30%
CraterTime
0.0 – 10.0 s
0.1 s steps. Factory setting
1. 0 s
Creep Start
10 – 99 %
1% steps. OFF, CURVE
(OFF = 100%)
Factory setting is CURVE (Creep Start value
comes from Welding Curve).
18
KempA
rc P
ulse
TCS / © Kemppi O
y / 1204