Kemppi Pulse 3000 MVU User Manual

Page 19

background image

EN

Calibration

42

CAL

X

X

1

V/100A Setting mid value of arc length

fine adjustment 0.0…10.0
V/100A

WFS

51

FS

18

m/min Wire feed maximum

18 or 25 m/min

Gun

53

Gun

On

Liquidcooled thermal protection
on/off

GunRemote

54

GrE

On

Disabling of gun remote control
automatic identification

Water Cooler

On/Off Selection

55

Coo

On

Set OFF after each power up if
cooler is connected with gas
cooled gun.

Display reset time

81

dLY

X

X

5

s

1...20 s

PRG INFO - feeld

selection

82

diS

X

X

1

1, 2, 3

Restore

99

FAC

X

OFF

Restoring factory settings
(OFF=no reset,
Pan=panel and setup
ALL= also memory channels)

Changing parameters

By pressing the 2T/4T (SETUP) selection switch a little longer the machine will enter the SETUP

state. The display will show the set parameter’s runnning number (blinking), its abbreviation

and value. Select the parameter number using the “SYNERGIC PRG” + and - buttons or the

“SETUP” button (which will jump by tens). Change the value using the control button (in some

cases, the value can be found from the synergy curve). “Syn” and the curve value will blink by

turns on the right of the display. Set the value by turning the button anticlockwise.
Exit for SETUP using a long press.
Frequency and amplitude of double pulse can be set in the separate ‘SET’ mode, obtained

by first pressing the 2T/4T (SETUP) and, without releasing it, the method button. “dFr” and

the frequency in Hz will be displayed. “Syn” will appear if the frequency is based on synergy

curves. Change this value by turning the control button anticlockwise. Press it twice to display

“dA” i.e. the amplitude (m/min). Adjust this accordingly and exit SETUP by pressing any button

other than SETUP.

3.3.13 error codes

Error codes are among others the following:
Err 3: Overvoltages in the mains supply. Also the pilot light of overvoltage is lighting.
Err 4: The thermal protection of power suorce has stopped welding. Also the pilot light of

thermal protection is lighting.
Err 5: The cooling device has stopped welding.
Err 6: The terminal voltage has rised. Take the device to service.
Err 153: Liquid cooled PMT- or WS-gun is overheated. Or torch-PTC or RMT10 has beeb

installed, but the jumber inside the torch is in FU-position, look also instruction of torch.
Err 154: Overloading of the wire feed motor
Error code is eliminated when the reason is aborted, except Err 6, which demands to turn

down the machine.

17

Kempac

t P

ulse 3000 MVU / © Kemppi O

y / 1026