the Hot start:

The Hot Start function is used with 1-MIG and pulse MIG welding. The Hot Start time by 4T

Hot Start time is determined by trigger function (see picture) and while by 2T function it

is determined by the SETUP parameters. The level of Hot Start can be changed by SETUP

function.
The Hot Start level, Hot Start time by 2T, crater fill level and downslope time can be easily

adjusted using the ‘QUICK SETUP’ function:

1.

Select the gun trigger function: 4T or 2T.

2.

First, press the SETUP button and then , while still pressing the SETUP button, press the

extra function button.

3.

Adjust the Hot Start level.

4.

Repeat step 2, upon which the display will show the next adjustable parameter,

depending on the switch mode.

Exit by pressing any button (except SETUP)

3.3.9 use of gas test

If you press the gas test button, gas will begin to flow without any starting power source or

wire feed. Gas flow can be measured by using an external measuring device.
Cut off the gas flow by pressing the same button again, or the gun trigger. If the trigger is not

pressed again, the gas flow will end within 20 seconds.
The display will show “GAS” and the time.

3.3.10 testing wire feed

The wire feed switch will start the wire feed motor without opening the gas valve. The power

source will start up, but without providing welding power. The wire feed range will be 5m/

min but can be adjusted as desired.

3.3.11 memory channels, memOrY

The pulse panel has 100 channels for different welding options. Memory channels can be

chosen on the lower part of the panel using the memory block. Both welding values and

functions can be saved. Do the following: