Kemppi Pulse 3000 MVU User Manual
Page 18

EN
1.
Press
twice if needed and and the SET light will start blinking if the channel is
not in use, while the light will stay on if the channel is in use.
2.
Select the memory channel you want by pressing CH button
3.
Make settings and save by pressing SAVE button.
4.
Press
twice. ON light turns on.
5.
Start welding and set the values.
To change the values, the light must be switched from the ON to SET and then you can choose
the parameters, pressing the SAVE button afterwards. It is also possible to save the used
parameters by pressing SET when memory function is OFF (no lights). The channel can be
emptied by pressing
and SET button in SET simultaneously.
using saved settings
1.
Press
button.
2.
Select the memory channel by pressing the CH button.
3.
Start welding.
memory channels in control device
Select memory channels by pressing the CH REMOTE button simultaneously and the gun
control light will start to blink. Use the saved values through the gun’s remote control.
You can use five channels.
3.3.12 setuP
Using the SETUP function, the user can change welding parameters which do not have their
own panel functions. These parameters can be set separately for 1-MIG and Pulse MIG. SETUP
settings are separate for each memory channel.
setup functions on pulse panel
Parameter Name Nr Display
1-MIG
Pulsed
MIG
Factory
value
Unit
Explanation
PostGasTime
1
PoG
X
X
Curve
s
PostGas time 0.0…9.9 s
PreGasTime
2
PrG
X
X
Curve
s
PreGas time, functions by 2T
0.0…9.9 s
HotStartLevel
11
Hot
X
X
30
%
Hot start ratio to welding power
-50…+75%
HotStartTime 2T
12
H2t
X
X
2
s
2T Hot start timer 0.1-9.9 s
CraterFillLevel
14
CFL
X
X
30
%
Welding end level 10-90 %
CraterFillSlope
15
CFS
X
X
1
s/10m
Wire slowing-down
1…20 s/10m
CreepStartLevel
17
CSL
X
X
Syn
Wire speed start value 10…90
CreepStartSlope
18
CSS
X
X
0
s/10m
Wire speed up time
0.1…5 s/10m
DoubleFrequency
21
dFr
X
Curve
Hz
Double pulse frequency control
0.4…8.0 Hz
DoubleAmpiltude
22
dA
X
Curve
m/min Double pulse power variation
control 0.1…3.0 m/min
StartPower
31
StP
X
X
0
Start power control
-9…0…+9
PulseCurrent
33
PuC
X
0
%
Pulse top current control
-10…+15%
ArcLength
AdjRange
41
ALr
X
X
0
%
Arc length adjustment range
-50…+75%
16
Kempac
t P
ulse 3000 MVU / © Kemppi O
y / 1026