Product specifications, 1 delivery form, 2 technical data – Ivoclar Vivadent EP3000-G2 User Manual
Page 35: 3 acceptable operating conditions, 4 acceptable transportation and storage conditions
![background image](https://www.manualsdir.com/files/791293/content/doc035.png)
35
9. Product Specifications
9.1 Delivery form
– Programat EP 3000/G2
– Programat fring tray Kit
– Firing plate
– Automatic Temperatur Checking Set 2 ATK 2 (Test Set)
– USB download cable
– USB Stick Programat
– PrograBase 2 Software
– Service passport equipment
– Operating Instructions
– Cooling grid
9.1.2 Recommended accessories
– Programat Accessories Set
– Automatic Temperature Checking Set 2 (ATK 2)
– Vacuum pump VP4
9.2 Technical data
Power supply
110–120 V / 50–60 Hz
200–240 V / 50–60 Hz
Overvoltage category II
Contamination level 2
Tolerated voltage fluctuations
+/- 10%
Max. power consumption
12 A at 110-120 V
8.5 A at 200-240 V
Acceptable data for vacuum pumps from other manufacturers
Max. output:
250 W / max. leakage current 0.75 mA
Final vacuum:
< 50 mbar
Use only tested pumps
Electrical fuses:
110–120 V:
250 V / T 15 A (heating circuit)
250 V / T 5 A (vacuum pump)
200–240 V:
250 V / T 8 A (heating circuit)
250 V / T 3.15 A (vacuum pump)
Dimensions of electrical fuses:
110–120 V:
Diameter 6.3 x 32 mm
200–240 V:
Diameter 5 x 20 mm
Dimensions of the closed furnace:
Depth: 430 mm / Width: 305 mm / 410 mm (with cooling tray)
Height: 565 mm
Usable size of the firing chamber:
Diameter 80 mm
Height 48 mm
Max. firing temperature:
1200 °C
Weight:
Furnace base: 12.0 kg
Furnace head: 7.0 kg
Safety information
The Programat EP 3000/G2 complies with the following guidelines:
– EN61010-1:2001 2
nd
Ed.
– IEC61010-1:2001 2
nd
Ed.
– UL/CSA61010-1:2004 2
nd
Ed.
– EN61010-2-010:2003 2
nd
Ed.
– IEC61010-2-010:2003 2
nd
Ed.
– CSA61010-2-010:2004 2
nd
Ed
Radio protection / electromagnetic compatibility
EMC tested
9.3 Acceptable operating conditions
Acceptable ambient temperature range:
+5 °C to +40 °C / +41 °F to +104 °F
Acceptable humidity range:
80% maximum relative humidity for temperatures up to 31 °C
(87.8 °F) gradually decreasing to 50% relative humidity at 40°C
(104 °F); condensation excluded.
Acceptable ambient pressure:
The furnace has been tested for use at altitudes of up to 2,000 m
(6562 ft.) above sea level.
9.4 Acceptable transportation and storage conditions
Acceptable temperature range: -20 °C to +65 °C / -4 °F to +149 °F
Acceptable humidity range:
Max. 80% relative humidity
Acceptable ambient pressure:
500 mbar to 1060 mbar
Use only the original packaging of the Programat EP 3000/
G2 together with the corresponding foam material for shipping
purposes.