4.5 Initial start-up
1. Connect the power cord with the wall socket.
2. Put the On/Off switch (11) at the rear of the furnace on position
„I“ and connect the vacuum pump.
4.5.1 Start screen
Immediately after switching on, the display briefly shows the start
screen.
4.5.2 Self-test
The furnace will automatically conduct a self-test after start. The per-
formance of all furnace components is automatically checked. The
display shows the following indications during the self-test:
1 Software version
2 Status bar
3 Firing hours
4 Current power supply
If a component is defective, the corresponding error number (ER xxx)
will be indicated in the display.
4.5.3 Selecting the operation mode
After the self-test, the selection screen for the operation mode will
be displayed. It is used to select the general operation mode (firing
or pressing). The operation mode selection can also be shown via the
Firing / Pressing key (93) if no program is active.
The cursor position (frame around
the symbol) can be changed by
means of the Cursor keys. The
marked operation mode can
finally be selected using the Enter
key.
This information is only shown if
the operation mode has been
changed. Make sure that the
furnace runs at the new stand-by
temperature long enough before
you start a program.
Use the ESC key to quit such messages (Info, Hint, Error). The
acoustic signal can be stopped any time by pressing the STOP key.
4.5.4 Basic build-up of screens
The different areas of the screen are shown with the press program
stand-by and operating screens as examples.
The uppermost line mainly shows status information. In the central
and largest area, important information of the respective screen are
displayed. The lowest line provides information about possible
activities (keystrokes). The command keys (Open furnace head, Close
furnace head, STOP, START keys) are not shown for reasons of clarity.
Recommendation
area
Main area
Operation mode
Status area
Furnace
temperature
Possible
keystrokes
Selected program,
investment ring
1
2
4
3