Partial crown
– Make sure that the preparation margins are not located in the area of static or dynamic
antagonist contacts.
– Provide at least 1.5 mm of space in the cusp areas.
– Prepare a circular shoulder with rounded inner edges or a chamfer at an angle of
approximately 20 to 30 degrees.
– Ensure that the width of the shoulder/chamfer is at least 1.0 mm.
Starting situation
Opening the cavity,
occlusal orientation grooves
Occlusal and oral reduction
of the cusp
Creating the circular
preparation margin
Smoothing the cusps
Proximal preparation
Proximal preparation
Finished and smoothed
preparation
1.5
1.5
1.5
1.0
1.5
Practical procedure for restorations with IPS e.max |
Preparation
LS
2
Clinical pictures: Prof. Dr D. Edelhoff, Germany
See also other documents in the category Ivoclar Vivadent Equipment:
- 14K (2 pages)
- 24K (2 pages)
- BioUniversal KFG (2 pages)
- Capricorn 15 (2 pages)
- Callisto 86 (2 pages)
- Harmony KF (2 pages)
- Callisto 86 (2 pages)
- BioUniversal KFG (2 pages)
- BioUniversal KFG (2 pages)
- BioUniversal E (2 pages)
- BioUniversal PdF (2 pages)
- Brite Gold (2 pages)
- Capricorn 15 (2 pages)
- Callisto Implant 33 (2 pages)
- Capricorn (2 pages)
- Colado CC (2 pages)
- Callisto 84 (2 pages)
- Callisto CP+ (2 pages)
- Callisto CPG (2 pages)
- Callisto Implant 60 (2 pages)
- CosmoPost (24 pages)
- Colado NC (2 pages)
- Elektra (2 pages)
- Evolution Lite (2 pages)
- ESPRIT (1 page)
- Elektra 10 (2 pages)
- IPS d.SIGN Ultra (2 pages)
- EP 5000 (1 page)
- Harmony 2 (2 pages)
- EP 600 (36 pages)
- Harmony Hard (2 pages)
- Harmony Medium (2 pages)
- Harmony Soft (2 pages)
- Heliobond (36 pages)
- Harmony 3 (2 pages)
- Harmony C&B 55 (2 pages)
- EP 600 Combi (40 pages)
- Harmony PF (2 pages)
- Harmony X-Hard (2 pages)
- IPS AcrylCAD (2 pages)
- IPS d.SIGN 30 (2 pages)
- IPS Classic (24 pages)
- IPS d.SIGN 59 (2 pages)
- IPS d.SIGN 84 (2 pages)
- IPS d.SIGN 96 (2 pages)