beautypg.com

Cut-back technique, Preparing for veneering – Ivoclar Vivadent IPS Empress Esthetic User Manual

Page 38

background image

38

Cut-back technique

Fabricate a silicone key to prepare the restorations for individualization with IPS Empress Esthetic Veneer. Subsequently, the

cut-back is carried out. The fully anatomically pressed veneers are reduced in the incisal third. For that purpose, use

ceramic-bonded grinding instruments or diamonds.

The following points must be observed:

– Too much pressure and excess heat development during grinding must be prevented.

– Refrain from designing too extreme mamelons with undercuts.

– Check the cut-back by means of the silicone key.

– The minimum wall thickness of the pressed IPS Empress Esthetic restorations of 0.5 mm must be observed.

Fabricate a silicone key before conducting the cut-back.

Refrain from designing too extreme mamelons with undercuts.

Check the cut-back by means of the silicone key, observe the minimum
wall thickness of 0.5 mm.

Limit the cut-back to the incisal third.

Blast the restoration with Al

2

O

3

(Type 100) at 0.5 bar pressure.

Clean the restoration with steam prior to wash firing.

Preparing for veneering

Blast the outer surfaces of the ceramic restoration carefully with Al

2

O

3

(Type 100) at max. 0.5 bar pressure and clean

thoroughly with the steam jet. Before veneering, the restorations must be free of dirt and grease.