The sprues are cut with a fine diamond disk.

Divested objects

When divesting the object, blast from the direction indicated in the schematic at the top. Note: Blast from the incisal and/or occlusal direction, if possible.

Removing the pressed object / finishing

The following procedure is recommended to finish IPS Empress Esthetic restorations:

– Wet the area to be ground and use a fine diamond disk to cut the sprues.

– Prevent overheating of the ceramic material. Low speed and light pressure is recommended.

– Smooth out the attachment points of the sprues.

– Remove the spacer prior to placing the pressed object on the die.

– Place the restoration on the die, check contact points and carefully adjust.

– Make sure that the minimum thicknesses are maintained even after finishing.

– Clean the restoration under running water or with steam before characterization.

– It is not necessary to blast the restoration with Al

2

O

3

prior to further processing.

Rough divestment is carried out with glass polishing beads at 4 bar (60 psi) pressure.

Fine divestment is carried out with glass polishing beads at 2 bar (30 psi) pressure.